Descargar Imprimir esta página

resideo Braukmann Z74S-AN Instrucciones De Instalación página 6

Actuador de enjuague inverso automáticoe
Ocultar thumbs Ver también para Braukmann Z74S-AN:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 26
4.3 Discharge of reverse rinsing water
Discharge lines are to be implemented according to
DIN EN 806.
The reverse rinsing water must be routed to the drain channel
in such a way that no backwater can occur.
To do this there are 3 options:
1.
Direct connection:
• Connector DN 50/70 as well as the necessary
pipes and siphon (3 elbows 90°) in DN 70.
2.
Discharge into floor drain
3.
Drain into open container.
Filter size
Discharge
connection
1
3
/
" and
/
"
DN 50
2
4
1
1" and 1
/
"
DN 70
4
*at 4 bar inlet pressure and 20 seconds reverse rinsing
duration
Reverse rinsing duration, approx. 20 s.
5
Commissioning
The device can be operated either using batteries or a
power supply unit.
5.1 Insert batteries
1.
Loosen fastening screws
2.
Open housing cover
3.
Insert batteries
4.
Close housing cover
5.
Tighten fastening screws
5.2 Connect power supply unit
1.
Insert plug on back of housing
2.
Insert power supply plug
5.3 Functional check
After applying supply voltage, a reverse rinsing is triggered.
The desired reverse rinsing interval can then be set.
GB
5.4 Set the reverse rinsing interval
Setting
OFF
TEST
1h
1d
Reverse
rinsing
6d
volume*
15d
10 litres
30d
12 litres
45d
2M
3M
1.
6
The reverse rinsing interval can be set to 8 different
intervals
The selection of the interval depends on the degree of
soiling of the water.
Interval
0
Test
1 hour
1 day
6 days
15 days
30 days
45 days
2 months
3 months
Turn setting knob to the desired reverse rinsing
interval
• Selection is confirmed by the flashing frequency
of the LED
• Directly after setting the reverse rinsing interval,
an automatic reverse rinsing is triggered
LED display
(flashes)
1x
2x
3x
4x
5x
6x
7x
8x
9x
10x
MU0H-1153GE23 R0823

Publicidad

loading