EN
Removing jams
If a jam occurs, fi rst remove the battery from the tool.
Then open the magazine fully and remove the fasteners from the magazine. Remove the fasteners which caused the jam. Place
the new fasteners in the magazine and close the magazine. Carry out a fastener fi ring test on waste material.
Illuminating light
The tool is equipped with a light to illuminate the fastener fi ring spot. The light comes on when the switch is pressed. The light turns
off automatically approximately 10 seconds after the last press of the switch. The light switch has been shaped and positioned in
such a way that closing your hand on the handle grip will turn the light on.
Additional notes
The stapler is not intended for construction work. It cannot be used for installing construction materials.
Fasteners should be fi red at right angles to the surface. Avoid fi ring fasteners at an angle.
Avoid pressing the trigger when the magazine is empty, so-called "dry fi ring". Failure to follow this rule may lead to faster wear of
the staple fi ring mechanism, resulting in incorrect product functioning.
Take regular breaks during work. Do not exceed the rated product capacity.
Do not overload the tool, the temperature of the external surface must never exceed 60
C.
O
MAINTENANCE AND OVERHAUL
ATTENTION! Before any adjustment, technical service or maintenance operations unplug the tool. Once the operations have been
fi nished, the technical conditions of the tool must be assessed by means of external evaluation and inspection of the following
elements: body and handle, conductor with a plug and defl ection, functioning of the electric switch, patency of ventilation slots,
sparking of brushes, noise level of functioning of bearings and gears, start-up and smoothness of operation. During the guarantee
period, the user cannot dismantle the electric tools or change any sub-assemblies or elements, since it will cancel any guarantee
rights. All irregularities detected at overhaul or during functioning of the tools are a signal to have the tool repaired at a service
shop. Once the functioning has been concluded, the casing, ventilation slots, switches, additional handle and protections must be
cleansed with a stream of air (at a pressure not exceeding 0.3 MPa), with a brush or a cloth without any chemical substances or
cleaning liquids. Tools and handles must be cleansed with a clean cloth.
O R I G I N A L
I N S T R U C T I O N S
13