MODEL: KYRA D 30 UNIT COND
Trademark: LAMBORGHINI
Condensing boiler: SI
Low-temperature boiler (**): NO
B1 Boiler: NO
Combination heater: NO
Cogeneration space heater: NO
Item
Seasonal space heating energy efficiency class (from A++ to G)
Rated heat output
Seasonal space heating energy efficiency
Useful heat output
Useful heat output at rated heat output and high-temperature regime (*)
Useful heat output at 30% of rated heat output and low-temperature regime (**)
Useful efficiency
Useful heat output at rated heat output and high-temperature regime (*)
Useful heat output at 30% of rated heat output and low-temperature regime (**)
Auxiliary electricity consumption
At full load
At part load
In standby mode
Other items
Standby heat loss
Ignition burner power consumption
Annual energy consumption
Sound power level
Emissions of nitrogen oxides
(*) High-temperature regime means 60°C return temperature at heater inlet and 80°C feed temperature at heater outlet.
(**) Low temperature means for condensing boilers 30°C, for low-temperature boilers 37°C and for other heaters 50°C return temperature (at heater inlet).
MODEL: KYRA D 30 SI UNIT COND
Trademark: LAMBORGHINI
Condensing boiler: SI
Low-temperature boiler (**): NO
B1 Boiler: NO
Combination heater: SI
Cogeneration space heater: NO
Item
Seasonal space heating energy efficiency class (from A++ to G)
Rated heat output
Seasonal space heating energy efficiency
Useful heat output
Useful heat output at rated heat output and high-temperature regime (*)
Useful heat output at 30% of rated heat output and low-temperature regime (**)
Useful efficiency
Useful heat output at rated heat output and high-temperature regime (*)
Useful heat output at 30% of rated heat output and low-temperature regime (**)
Auxiliary electricity consumption
At full load
At part load
In standby mode
Other items
Standby heat loss
Ignition burner power consumption
Annual energy consumption
Sound power level
Emissions of nitrogen oxides
For combination heaters
Declared load profile
Water heating energy efficiency class (from A to G)
Daily electricity consumption
Annual electricity consumption
Water heating energy efficiency
Daily fuel consumption
Annual fuel consumption
(*) High-temperature regime means 60°C return temperature at heater inlet and 80°C feed temperature at heater outlet.
(**) Low temperature means for condensing boilers 30°C, for low-temperature boilers 37°C and for other heaters 50°C return temperature (at heater inlet).
EN
60
ErP product fiche
ErP product fiche
KYRA D
Symbol
Unit
Pn
kW
ηs
%
P4
kW
P1
kW
η4
%
η1
%
elmax
kW
elmin
kW
PSB
kW
Pstby
kW
Pign
kW
QHE
GJ
LWA
dB
NOx
mg/kWh
Symbol
Unit
Pn
kW
ηs
%
P4
kW
P1
kW
η4
%
η1
%
elmax
kW
elmin
kW
PSB
kW
Pstby
kW
Pign
kW
QHE
GJ
LWA
dB
NOx
mg/kWh
Qelec
kWh
AEC
kWh
η
%
wh
Qfuel
kWh
AFC
GJ
Value
A
29
91
28,5
6,6
91,0
97,5
0,188
0,075
0,003
0,100
0,000
70
66
86
Value
A
29
91
28,5
6,6
91,0
97,5
0,188
0,075
0,003
0,100
0,000
70
66
86
XL
A
0,250
55
81
24,158
19
A73023800

Publicidad

loading

Este manual también es adecuado para:

Kyra d 30 unit condKyra d 30 si unitKyra d 30 si unit cond