Descargar Imprimir esta página

DINUY DM TEC 003 Instrucciones De Uso página 5

Detectores empotrable techo

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

EN
INSTRUCTIONS MANUAL
Ref. DM TEC 003, DM TEC 03N, DM TEC 03P,
DM TEC 111 and DM TEC 11N
FLUSH-CEILING MOUNTED MOTION DETECTOR
TECHNICAL SPECIFICATIONS
References
Power supply
Power consumption
Load
LED lamps
Incandescence
230V Halogens
LV Halogen with
Electronic transfo
LV Halogen with
Ferromagnetic transfo
Fluorescence
PL lamps
Detection angle
Range of coverage
Settings
Level of luminosity
Timing
Environmental
protection
Operating
temperature
CHARACTERISTICS
● Indoor movement detector for flush-ceiling mounting.
● Circular detection area, 360º.
● One switching no-free-voltage output.
● High capacity relay with "zero crossing" control, which allows
switching practically any type of load.
● Natural light measurement, allowing condition its operation to
daylight level.
● High sensitivity PIR sensor, which detects very small movements.
● Possibility to connect several detectors in parallel to expand the
area to be covered in a single line of lighting.
● A red LED is equipped as an indicator for test triggering
● Optional IR remote control for easy and quick setting
(EM MAN DM0).
DIMENSIONS
63,5mm
INSTALLATION
● A. Setting the device:
Given that the sensor responds to movement and to heat, avoid
the following situations:
- Pointing the detector towards objects with reflective surfaces
such as mirrors.
- Positioning the sensor near heat sources such as ventilation
systems, air conditioning devices or lamps.
- Pointing te detector towards objects which could be moved by
draughts, such as curtains, plants...
Take into account the walking direction when installing. It is less
sensitive to movement across the detector and more sensitive to
movement directly toward the sensor, which will reduce the
detection coverage
Walking towards:
● B. Mounting:
Drill a hole of Ø65mm in the ceiling:
RANGE
● The optimal height for its assembly is 2,5m, which can cover up to
Ø7m.
Maximum sensitivity area
DM TEC 003
DM TEC 03N
DM TEC 03P
230V~ ±10%
18x7W, 12x11W, 10x15W, 10x20W, 10x23W
360º, max. Ø7 at 2,5m high and 18ºC
45mm
63,5mm
.
More sensitive
~50/60Hz
16A cos φ = 1
3.000W
3.000W
3.000W
2.400W
1.300W (130µF)
Via Potentiometer or remote control
(EM MAN DM0)
3Lux a 1.000Lux
5 seconds .. 10 minutes
IP40, Class II
–10ºC .. +45ºC
Ø
3m
Ø
7m
DM TEC 111
DM TEC 11N
110V~ ±10%
60Hz
<1W
400W
360º
80mm
Walking across:
Less sensitive
2,5m

Publicidad

loading

Productos relacionados para DINUY DM TEC 003

Este manual también es adecuado para:

Dm tec 03nDm tec 03pDm tec 111Dm tec 11n