WIRING DIAGRAMS
• Installation of electric equipment must be carried out
by qualified professionals.
• Before you start making any connections, disconnect
the power supply to avoid any risk.
• When some kinds of lamps blow, they can produce a
very high current which could damage the detector.
NOTE
The two "L" terminals are internally connected.
● Follow one of the following diagrams to make the connections:
- Simple installation:
- Installation of 2 detectors in parallel:
- Installation with a Switch for activate or deactivate manually
the movement detection:
- Installation with a Switch for permanent ON:
- Installation with Staircase lighting timer (MI EL3 003):
L
N
- Installation with Timer (MI PLA 002) and buttons in parallel,
each one with its timing:
L
N
SETTINGS AND TEST
SETTINGS
● "Lux" and "Time" values can be adjusted via the control knobsof the
detector or with an optional IR remote control (EM MAN DM0).
● Adjust the 'Lux' and 'Time' control knobs according to the desired
values.
- Lux Settings (LUX)
This setting allows to select the minimum level of natural light in
wich the detector would detect movement. In case it detects
movement and natural light is below the indicated level, the
device will not respond.
The user can set this value between 3 and 100 Lux.
If the detector is expected to work despite of surrounding
natural light, set the potentiometer in "
On the contrary, if you want the detector to work only at night
(without any natural light), set the potentiometer on "
- Time Settings (TIME)
This setting allows to select the span of time during which
lamps will remain on, after movement detection.
Timing starts whenever movement is detected.
This time can be set between 5sec and 10min.
- Settings carried out using remote control (EM MAN DM0)
The Time and Lux settings can be adjusted via this remote
control, without need to access to the potentiometers.
Detector's LED behavior when using the remote control:
- The LED will blink twice as soon as it receives a telegram
from the remote control..
- The LED will be on for 1s and off for 5s after receiving a
'Permanent ON/OFF' signal from the remote control
WORKING TEST
● The purpose of the test procedure is to check and adjust the
coverage pattern of the motion sensor when it is connected for the
first time.
NOTE
Once the detector is connected to power, it is necessary to
wait 2 minutes for its stabilization. During this time, the device
activates its output and does not respond to movement.
● The red LED, which is within the lens, can be used as an indicator
when performing the test procedure, without any load.
● This LED lights whenever movement is detected and stays on until
the time delay expires.
● Turn the "LUX" control knob to "
● Walk from outside across to the detection pattern until the LED and
load turn on..
● Once verified that the operation is successful, set the detector to
the desired values.
MASKING CLIPS
● There are three covers available to restrict the coverage area.
● To fix the restriction covers, the decorative frame has a slot on its
rear side, where the projection of the cover fits.
CAUTION: Dangerous voltage!
L
N
L
N
N L
L
N
L
N
N L
L
L
MI PLA 002
Load
N L
L
L
Load
L
L
Load
N
L
L L
N L
L
L
2
4
MI EL3 003
N L
LUX
TIME
" and "TIME" to " - ".
N L
L
L
Switch
Switch
1
3
L
L
".
".

Publicidad