Descargar Imprimir esta página

Garland AMURA SUPRA 1012 PLCE Manual De Instrucciones página 29

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 1
damages. Tighten, repair or replace the pieces that
you have noticed not to be in a perfect working order.
Do not use the machine if it has lose or damaged
pieces.
5.3.1. VERIFICATION OF THE ELECTRICAL
CONNECTION
Check that the connection to the mains is correct and
that the electric current is adequate for the machine.
Any attachments must comply with to the needs of
this machine.
Check that the cable is behind the machine and never
in the working area.
5.3.2. VERIFICATION OF WATER CONNECTION
Open the water intake and check that there are no
leakages. If there are any leakages, replace or repair
the hoses or its connectors.
5.3.3. PLACEMENT OF THE MACHINE
Ensure the machine is in a vertical and stable position.
5.4. START UP AND STOPPAGE
The gun has a closing security device
that if in place will not allow the gun to
function.
Before starting the machine, the machine
must have its internal circuit full of water.
To fill, push the trigger of the gun with
the machine stopped (switch in the ¨o¨ position) until
water with no pressure drips from the lance. If the
pump works with the internal circuit not full of water
(working in dry conditions), the pump will be damaged.
Start up:
Place the switch in position ¨1¨.
Remove the blocking security
device of the gun and action the
trigger.
Stoppage:
Place the switch
in the ¨O¨ position.
The engine of the
machine will stop.
The TSS system allows the engine to stop when the
trigger is not pressed. For a proper usage, once the
trigger is not pressed, we should wait 4 or 5 seconds
before pressing the trigger again.
If the machine has not been used for a couple of
minutes you must place the On/Off switch to the Off
position ¨O¨.
NOTE: When pressing the trigger, the power
of the water forwards will have a back pull
on the user. Always hold the lance with two
hands and tightly and always be in a stable position to
avoid falling over or watering unwanted areas.
5.5. VERIFICATION AFTER USE
Check that when the trigger is not pressed, water
does not flow out under pressure through the lance,
hose or any connectors.
If you detect any of these leakages please tighten or
repair these parts.
29/96
English
Interruptor On/Off
Security device of
the gun

Publicidad