Safety instructions
■
Salt water
■
Foodstuffs
■
aggressive media, chemicals
■
corrosive, flammable, explosive or fuming flu-
ids
■
fluids that are hotter than 35 °C
■
water containing sand and abrasive fluids.
3 SAFETY INSTRUCTIONS
DANGER! Danger from contact with live
parts! A defect in the pump or the extension ca-
ble can result in serious injury!
■
Disconnect the connector plug from the
mains immediately.
■
Connect the device via an earth leakage cir-
cuit breaker with a rated leakage current of
< 30 mA.
WARNING! Risk of injury. Defective and
disabled safety and protective devices can result
in serious injury.
■
Have any defective safety and protective de-
vices repaired.
■
Never disable safety and protective devices.
CAUTION! Risk of burns from hot water!
After extended use against the closed pressure
side (> 10 min.), the water in the pump can be-
come very hot and may escape uncontrolled!
■
Disconnect the pump from the mains supply
and allow the pump and water to cool down.
■
Check the water level on the suction side.
■
Check the leak-tightness of the lines.
■
Check the installation of the suction and
pressure lines.
■
Put the pump into operation again only after
all the faults have been remedied!
3.1
General safety warnings
■
Appliances can be used by persons with re-
duced physical, sensory or mental capabili-
ties or lack of experience and knowledge if
they have been given supervision or instruc-
tion concerning use of the appliance in a safe
way and if they understand the hazards in-
volved. Children shall not play with the appli-
ance.
■
People with very strong and complex restric-
tions may have needs that exceed the in-
structions described here.
467772_j
■
Pumps without indication that they are pro-
tected against the effect of freezing shall not
be left outside during freezing weather condi-
tions.
■
Never lift, transport or affix the pump by the
mains cable. Do not pull the mains cable in
order to pull the mains plug out of the socket.
■
Unauthorised modifications or conversions to
the pump are prohibited. Repairs may only
be carried out by our customer service.
■
Disconnect the mains plug before working on
the device. Protect the mains plug against
moisture.
■
Only use the pump and extension cable if
they are in flawless technical condition. Dam-
aged appliances must not be operated.
■
Maintain a safe distance to persons or ani-
mals or switch off the pump if animals ap-
proach.
3.2
Electrical safety
■
The pump may not be operated while people
are in the pool or pond.
■
The mains voltage at your location must com-
ply with the information regarding mains volt-
age in the Technical Data. Do not use any
other supply voltage.
■
The pump may only be operated on an elec-
trical installation in accordance with DIN/VDE
0100, parts 737, 738 and 702. For fuse pro-
tection, a circuit breaker of 10 A and an earth
leakage circuit breaker with a rated leakage
current of 10/30 mA must be installed.
■
Only use extension leads approved for out-
door use with a minimum cross-section of
2
1.5 mm
. Always fully unwind cable drums.
■
Damaged or fragile extension cables may not
be used.
■
Check the condition of your extension
lead prior to every use.
■
If the connection cable must be extended,
only a cable type H07RN-F and a moulded
sleeve must be used. This work must only be
carried out by an electrician.
■
If the supply cord is damaged, it must be re-
placed by the manufacturer, its service agent
or similarly qualified persons in order to avoid
a hazard.
17