Loader pump
1 Pull follower rod and engage follower by
rotating rod
2 Seat loader fitting into loader coupler
2.1 Push down to hold coupler valve open
3 Operate pump and view movement of
follower rod
4 Discontinue pump operation once groove
on follower rod is visible
5 Disengage follower rod from follower and
push into grease cylinder
CAUTION

Loader fitting on gun must mate with
loader coupler Pump may not operate if
components are not compatible
Prime gun
In most cases gun will prime simply by
operating trigger several times Should
grease fail to appear, air must be bled
Force prime
This process manually assists air to be
released from bleed valve
1 Pull follower rod and engage follower by
rotating rod
2 Open vent valve by unscrewing stem
approximately two turns
3 Push on follower rod
4 Once air is eliminated, tighten stem of
vent valve
5 Operate gun several times
6 Once grease appears, disengage follower
rod from follower and push into
grease cylinder
Check valve contamination
Outlet check may be held open should gun
fail to prime Remove plug (12), clean
ball (10), and ball seat of head (14)