■ Parameters for reading out and configuring
1. Reading outparameters
From home page, press
Temperature area display parameter code, clock area display value.
Press
or
Press
button or
return to the home page.
List of parameters refer to table below:
Parameter No
F0
F1
F2
F3
F4
F5
F6
F7
2. Configuring parameters
From home page, press
configuring page.
Temperature area display parameter code, clock area display value.
Press
or
Press
button for confirmation or scroll to next parameter.
Press
button or
return to the home page.
List of parameters can be configured refer to table below:
Parameter No
S0
S1
S2
S3
S4
S5
S6
S7
S8
S9
SA
Sb
Sc
SE
SF
SH
button for 3s to enter parameters page.
button to scroll down/up.
button or without any operation within 30 seconds, the system will
Description
Discharge temperature
Ambient temperature
Evaporator coil temperature
Suction temperature
Open pulse of EEV
Controller version No.
PCB version No.
Solar collector temperature
and
button and adjust the data of special parameters.
button or without any operation within 30 seconds, the system will
Description
Defrost exit temperature
Defrost cycle
Defrost operation time
Correction for tank water temperature
Tank water temperature differential
Defrost enter temperature
Status of anti-freeze
Status of anti-legionella
Status of Photovoltaic
Tset for timer 1
Tset for timer 2
Tset for timer 3
Status of solar pump
Status of E-Anode
Status of Wi-Fi
Clock of anti-legionella start
Range
0~130℃
-30~100℃ Display "--" when faulty
-30~100℃ Display "--" when faulty
-30~100℃ Display "--" when faulty
0~150℃
button at the same time for 3s to enter into parameter
0-deactivate,1-activate
0-deactivate,1-activate
0-deactivate,1-activate
0-deactivate,1-activate
0-deactivate,1-activate
0-deactivate,1-activate
24
Remark
Display "--" when faulty
Display "--" when faulty
Range
5~30 ℃
10~90 minutes
5~18 minutes
-5~5 ℃
2~12 ℃
-10~5 ℃
40~75 ℃
40~75 ℃
40~75 ℃
01:00~24:00
Default
20
45
10
0
5
-10
1
0
0
50
65
65
0
1
1
02:00