Descargar Imprimir esta página

Buffalo CU614 Manual De Instrucciones página 6

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 32
EN
Note: Failure to clean the appliance regularly may result in premature activation of the
thermal cut-out switch.
Remove the frying basket first, then remove the head unit for ease of cleaning.
Empty the oil tank to clean the appliance thoroughly.
Warning: Do not remove the oil tank until AFTER it has been emptied.
If the remaining oil is to be reused, filtering it before refilling will extend the oil's cooking life.
Use a suitable detergent to clean the interior of the appliance.
Use warm, soapy water and a damp cloth to clean the exterior of the appliance.
Dry thoroughly after cleaning, ensure there is no water left in the fryer.
Clean all removable parts
Use warm, soapy water and a soft brush to clean the lid, basket, batter plate and oil tank.
Dry thoroughly.
Troubleshooting
A qualified technician must carry out repairs if required.
Fault
Probable Cause
The appliance is
The unit is not switched on Check the unit is plugged in correctly and switched on
not working
Plug or lead is damaged
Fuse in the plug has blown
Mains power supply fault
Thermal cut-out switch is
activated
Safety switch not located
properly
Appliance does
Faulty thermostat
not reach set
Faulty element
temperature
Build-up of fat on the
element
Appliance heats up
Indicator light has expired
but indicator light
does not come on
HEAT indicator
Faulty element
light comes on but
Faulty thermostat
appliance does not
heat up
Thermostat set incorrectly
Oil overheats or
Thermostat damaged
starts to smoke
6
CU614-CU615-CU616-CU618_ML_A5_v1_20240207.indb 6
Solution
Replace plug or lead
Replace the fuse
Check mains power supply
Check the appliance is safe with no obvious damage
then press the reset switch on the rear
Refit head unit
Consult a qualified technician
Consult a qualified technician
Clean the appliance
Consult a qualified technician
Consult a qualified technician
Consult a qualified technician
Check thermostat
Switch off immediately. Consult a qualified technician
2024/2/7 14:35:03

Publicidad

loading

Este manual también es adecuado para:

Cu615Cu616Cu618