Descargar Imprimir esta página

Johnson COCI50B3B Manual De Instrucciones página 56

Cocina de gas

Publicidad

Idiomas disponibles

Idiomas disponibles

Electrical Connection
1. Your oven requires 16 or 32 Ampere fuse according to the appliance's power.
If necessary, installation by a qualified electrician is recommended.
2. Your oven is adjusted in compliance with 220-240V AC/380-415V AC
50/60Hz.electric supply. If the mains are different from this specified value,
contact your authorized service.
3. Electrical connection of the oven should only be made by the sockets with
earth system installed in compliance with the regulations. If there is no proper
socket with earth system in the place where the oven will be placed,
immediately contact a qualfied electrician. Manufacturer shall never be
responsible from the damages that will arise because of the sockets connected
to the appliance with no earth system. If the ends of the electrical connection
cable are open, according to the appliance type, make a proper switch installed
in the mains by which all ends can be disconnected in case of connecting /
disconnecting from / to the mains.
4. If your electric supply cable gets defective, it should definitely be replaced by
the authorized service or qualfied electricians in order to avoid from the
dangers.
5. Electrical cable should not touch the hot parts of the appliance.
6. Please operate your oven in dry atmosphere.
Electrical connection scheme
380-415V 3N~50/60Hz 380-415V 2N~50/60Hz
220-240V~50/60Hz
220-240V~50/60Hz
Neutral
Live
Phase
Earth
H05 VV-F 3G 4 mm²
H05 VV-F 3G 4mm² H05 VV-F 5G 1.5mm² H05 VV-F 4G 1.5mm² H05 VV-F 3G 1.5mm²
H05 VV-F 5G 1.5 mm²
15
400V 3N~50/60Hz
400V 2N~50/60Hz
L3
L2
Neutral
L2
L1
Earth
L1
H05 VV-F 4G 1.5 mm²
220-240V~50/60Hz
220-240V~50/60Hz
Neutral
L1
Neutral
Earth
Earth
H05 VV-F 3G 1.5 mm²