Descargar Imprimir esta página

Tripp-Lite SmartPro 2U SMART750RMXL2U Manual Del Propietário página 20

Publicidad

Idiomas disponibles

Idiomas disponibles

Specifications
Model
Nominal voltage and input range
Nominal input frequency and tolerance
Nominal output voltage
Nominal output frequency
Output voltage regulation in
line-mode
Output voltage regulation in
battery mode
Nominal output power in W / VA
Output voltage waveform
Maximum output current @ P . F.
Efficiency with nominal load
Maximum operating altitude
at 100% of nominal power
Online overload capability
Overload capacity in battery mode
Current limitation
Autonomy time at full load
Battery recharge time
Transfer time
Outlets
Maximum input current
SMART750RMXL2U
120V~, 83-147V
60 Hz (+/- 5 Hz)
120V~ in line mode
and 120V~ in battery
mode
60Hz (+/- 0.5 Hz)
120 V~ (+8% / - 21%)
120 V~ (+/-5%)
600W / 750VA
Sinusoidal in line mode
and in battery mode
6.3A
P .F. = 0.8
95%
6561 ft. (2000 m)
125% for 10 minutes
105% @ 0.5 seconds
10A
8.3 minutes @ 600W
4.5 hours
2 milliseconds typical
(4 milliseconds max)
6x 5-15R outlets with
battery backup,
regulation and surge
7.5A
20
SMART1000RM2U
120V~, 83-147V
60 Hz (+/- 5 Hz)
120V~ in line mode
and 120V~ in battery
mode
60Hz (+/- 0.5 Hz)
120 V~ (+8% / - 21%)
120 V~ (+/-5%)
800W / 1000VA
Sinusoidal in line mode
and in battery mode
8.3A
P .F. = 0.8
95%
6561 ft. (2000 m)
125% for 10 minutes
105% @ 0.5 seconds
10A
5.3 minutes @ 800W
4.5 hours
2 milliseconds typical
(4 milliseconds max)
2 milliseconds typical
(4 milliseconds max)
9.2A

Publicidad

loading

Este manual también es adecuado para:

Smartpro 2u smart1000rm2u