Descargar Imprimir esta página
NuTone QTREN080FL Manual Del Usuario
NuTone QTREN080FL Manual Del Usuario

NuTone QTREN080FL Manual Del Usuario

Ventilador/lampara/lamparas de noche

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

QTRN / QTREN SERIES
FAN / LIGHT / NIGHT LIGHTS
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-
JURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufac-
turer. If you have questions, contact the manufacturer at the
address or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a quali-
fied person(s) in accordance with all applicable codes and stan-
dards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhaust-
ing of gases through the flue (chimney) of fuel burning equip-
ment to prevent backdrafting. Follow the heating equipment
manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code au-
thorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Acceptable for use over a tub or shower when connected to a
GFCI (Ground Fault Circuit Interrupter) - protected branch cir-
cuit.
8. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not use to exhaust haz-
ardous or explosive materials and vapors.
2. This product is designed for installation in ceilings up to a 7/
12 pitch (Models QTRN080L and QTRN110L) or a 12/12
pitch (Models QTREN080FL and QTREN110FL). Duct con-
nector must point up. DO NOT MOUNT THIS PRODUCT IN A
WALL.
3. To avoid motor bearing damage and noisy and/or unbal-
anced impellers, keep drywall spray, construction dust, etc.
off power unit.
4. Please read specification label on product for further infor-
mation and requirements.
Installer: Leave this manual with the homeowner.
MODELS QTRN080L • QTREN080FL • QTRN110L • QTREN110FL
®
CLEANING & MAINTENANCE
For quiet and efficient operation, long life, and attractive appear-
ance - lower or remove grille and vacuum interior of unit with the
dusting brush attachment.
The motor is permanently lubricated and never needs oiling. If
the motor bearings are making excessive or unusual noises,
replace the motor with the exact service motor. The impeller should
also be replaced.
OPERATION
The fan, light, and night light can be operated separately. Use a
3-function wall control. Do not use a dimmer switch to operate
the light (Models QTREN080FL and QTREN110FL only). See
"Connect Wiring" for details.
WARRANTY
NUTONE THREE YEAR LIMITED WARRANTY
NuTone warrants to the original consumer purchaser of its products that
such products will be free from defects in materials or workmanship for
a period of three years from the date of original purchase. THERE ARE
NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT
NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY
OR FITNESS FOR A PARTICULAR PURPOSE.
During this three-year period, NuTone will, at its option, repair or re-
place, without charge, any product or part which is found to be defec-
tive under normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP
STARTERS AND TUBES. This warranty does not cover (a) normal main-
tenance and service or (b) any products or parts which have been subject
to misuse, negligence, accident, improper maintenance or repair (other
than by NuTone), faulty installation or installation contrary to recom-
mended installation instructions.
The duration of an implied warranty is limited to the three-year period as
specified for the express warranty. Some states do not allow limitation on
how long an implied warranty lasts, so the above limitation may not apply
to you.
NUTONE'S OBLIGATION TO REPAIR OR REPLACE, AT NUTONE'S
OPTION, SHALL BE THE PURCHASER'S SOLE AND EXCLUSIVE
REMEDY UNDER THIS WARRANTY. NUTONE SHALL NOT BE LI-
ABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES
ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR
PERFORMANCE. Some states do not allow the exclusion or limitation
of incidental or consequential damages, so the above limitation may
not apply to you.
This warranty gives you specific legal rights, and you may also have
other rights, which vary from state to state. This warranty supersedes all
prior warranties.
To qualify for warranty service, you must (a) notify NuTone at the ad-
dress or telephone number stated below, (b) give the model number
and part identification and (c) describe the nature of any defect in the
product or part. At the time of requesting warranty service, you must present
evidence of the original purchase date.
NuTone, Inc., 4820 Red Bank Road, Cincinnati, OH 45227
(1-800-543-8687)
Page 1

Publicidad

loading

Resumen de contenidos para NuTone QTREN080FL

  • Página 1 3. To avoid motor bearing damage and noisy and/or unbal- To qualify for warranty service, you must (a) notify NuTone at the ad- dress or telephone number stated below, (b) give the model number anced impellers, keep drywall spray, construction dust, etc.
  • Página 2 MODELS QTRN080L • QTREN080FL • QTRN110L • QTREN110FL ® Page 2 TYPICAL INSTALLATIONS PLAN THE INSTALLATION ROOF CAP 4-IN. ROUND DUCT Housing mounted to I-joists. WALL 4-IN. ROUND Use I-joist spacer block (provided). Purchase ELBOW separately The unit will operate most quietly and efficiently when located where the shortest possible duct run and minimum number of elbows will be needed.
  • Página 3 MODELS QTRN080L • QTREN080FL • QTRN110L • QTREN110FL ® Page 3 INSTALL HOUSING & DUCT CONNECT WIRING 1. Bend housing tabs. Use a pliers to bend housing TABS out to 90 TABS “FL” models only. 2. Mount SPACER housing to (use for mounting to I-Joist) joist.
  • Página 4 MODELS QTRN080L • QTREN080FL • QTRN110L • QTREN110FL ® Page 4 8. Push grille against ceiling. 9. Remove light lens. Carefully insert a small flat-blade screwdriver between grille and lens. Pry lens out. SERVICE NOTE To remove Blower Assembly: 10. Install light bulbs.
  • Página 5 PARA UN PROPÓSITO PARTICULAR. ASHRAE) y las autoridades de los códigos locales. Durante este período de tres años, NuTone, a su criterio, reparará o reemplazará, 5. Al cortar o perforar a través de la pared o del cielo raso, no dañe el sin cargo alguno, cualquier pieza o producto que se encuentre defectuoso bajo cableado eléctrico ni otros servicios ocultos.
  • Página 6 MODELOS QTRN080L • QTREN080FL • QTRN110L • QTREN110FL ® Página 6 INSTALACIONES TÍPICAS PLANIFICACIÓN DE LA INSTALACIÓN TAPA DE TECHO * CONDUCTO REDONDO DE 4 PULG. * Montaje de la cubierta en viguetas "I". Utilice un taco separador de viguetas "I" (suministrado).
  • Página 7 MODELOS QTRN080L • QTREN080FL • QTRN110L • QTREN110FL ® Página 7 INSTALE LA CUBIERTA CONEXIÓN ELÉCTRICA Y EL CONDUCTO 1. Doble las lengüetas de la cubierta. Con un alicate, doble las LENGÜETAS LENGÜETAS de la cubierta a 90°. modelos “FL” solamente.
  • Página 8 MODELOS QTRN080L • QTREN080FL • QTRN110L • QTREN110FL ® Página 8 8. Empuje la rejilla contra el cielo raso. 9. Saque la lente de la lámpara. Con cuidado, inserte un destornillador plano pequeño entre la parilla y la lente de NOTA DE SERVICIO lámpara.

Este manual también es adecuado para:

Qtren serieQtrn080lQtrn serieQtrn110lQtren110fl