Contents
General instructions ........................... 19
Safety information .............................. 19
Intended use ...................................... 20
Environmental protection ................... 20
Accessories and spare parts.............. 20
Scope of delivery ............................... 20
Description of the unit ........................ 20
Symbols on the device....................... 21
Initial startup....................................... 21
Operation ........................................... 22
Transport............................................ 26
Storage .............................................. 26
Care and maintenance....................... 26
Troubleshooting guide........................ 29
Disposal ............................................. 29
Warranty............................................. 29
Technical data .................................... 29
Declaration of Conformity .................. 30
General instructions
Read these original instruc-
tions before using your device
for the first time, adhere to the instructions
contained therein and store them for later
reference or subsequent owners.
● Be sure to read the safety instructions
no. 5.956-249.0 prior to the initial start-
up.
● If the operating instructions and safety
instructions are not observed, the device
can be damaged and dangers could
arise for users and other persons.
● Notify the dealer immediately in the case
of shipping damage.
Safety information
Hazard levels
DANGER
● Indication of an imminent threat of danger
that will lead to severe injuries or even
death.
WARNING
● Indication of a potentially dangerous situ-
ation that may lead to severe injuries or
even death.
CAUTION
● Indication of a potentially dangerous situ-
ation that may lead to minor injuries.
ATTENTION
● Indication of a potentially dangerous situ-
ation that may lead to damage to proper-
ty.
General safety instructions
DANGER ● Only trained personnel are
permitted to use the device and the sub-
stances for which it is to be used, including
the safe procedure for disposing of the vac-
uumed material. ● An air exchange rate L
must be present in the room when the ex-
haust gas is returned into the room. To re-
main within the required limit values, the
volume flow of returned air must be no
greater than 50% of the fresh air volume
(room volume V
Without special ventilation measures, the
following applies: L
contains dust that is harmful to your health.
Emptying and maintenance, including re-
moval of the dust bag, may only be per-
formed by technical specialists wearing
suitable personal protective equipment.
● Do not operate the device without the
complete filtration system. ● Observe the
applicable safety instructions for the mate-
rials being vacuumed.
WARNING ● The device must not be
used or stored outdoors in wet conditions.
● Apply the parking brake at the steering
roller to ensure a secure footing for the de-
vice. The device may move uncontrollably if
the parking brake is open.
CAUTION ● In case of longer breaks in
operation and after use, switch off the de-
vice at the power switches and unplug the
mains plug.
Behaviour in the event of an
DANGER
Risk of injury and damage in the event
of a short-circuit or other electrical
faults
Danger of electric shock, danger of burns
Switch off the device and unplug the mains
plug.
English
x air exchange rate L
R
-1
=1h
. ● This device
W
emergency
).
W
19