Descargar Imprimir esta página

Carbest CampCooler 30 Manual Del Usuario página 17

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 38
CARBEST CampCooler| 71456 / 71457 / 71458
9. TROUBLESHOOTING
• The product is not working:
If using the DC cable please ensure the cable still works.
Check that the power supply is working.
Check if the plug and socket are connected.
Check the fuse.
Check that the power switch is ON.
Compressor starts delay protection for 3 minutes after turning on.
• Food inside the product is frozen:
Temperature is set too low.
• Water flowing sound inside the tank:
Refrigerant is flowing, this is normal.
• Water drops around the case or door gap:
When moisture in the air meets the lower temperature case, it will naturally become liquefied and
condensed. Wipe away with a towel or soft cloth.
• Code F1 displayed:
Low voltage protection, which can be solved by setting the battery protection button
from H to M or from M to L.
• Code F2 displayed:
Fan overload protection. Please turn off the product and restart it after 30 minutes.
lf the code displays again, please contact the place of purchase.
• Code F3 displayed:
Compressor frequent start protection. Please turn off the product and restart it after 30 minutes.
lf the code displays again, please contact the place of purchase.
• Code F4 displayed:
Compressor is overloaded or working at a low speed. Please turn off the product and restart it after
30 minutes. lf the code displays again, please contact the place of purchase.
• Code F5 displayed:
High temperature compressor module protection. Please move the product to a ventilated area and turn
it off for 30 minutes then restart it. lf the code displays again, please contact the place of purchase.
• Code F6 displayed:
No parameter can be detected by the controller. Please restart the product.
lf the code displays again, please contact the place of purchase.
• Code F7 / F8 displayed:
Temperature sensor error protection. Please check the sensor terminal.
17
EN

Publicidad

loading

Este manual también es adecuado para:

Campcooler 40Campcooler 50714587145771456