INSTALLATION
The device must be installed as shown in the figure.
WALL-FITTED
CWITH EXTERNAL
WIRING
WIRES
BASE
COVER
WALL
All terminal boards can be removed to facilitate
maintenance operations. Wire separators are
provided.
To remove the terminal boards, pull the upwards
levering with a screwdriver where needed (see
figure).
Four holes are provided in the device for fastening
to the wall with expansion bolts diameter 6 mm (not
provided).
DS1072-020B
WALL-FITTED
WITH FLUSH
WIRING
DUCT + WIRES
BASE
COVER
DUCT + WIRES
WALL
WIRE CROSS-SECTION AREAS
Maximum distance
Between:
− PABX
− PABX interface
Between:
− Bus coupler
− PABX interface
Between:
− Video module
− PABX interface
CONNECTING THE VIDEO MODULE
The wire used for connecting the video bracket
is NOT provided. Use the wire provided with the
bracket and proceed as follows.
1) Cut one of the two wire connectors.
2) Extend the wire.
3) Connect the wire to the 1072/67 respecting the
polarity shown in the figure.
Max. 10 m
PROGRAMMING AND DELETING
The interface is equipped with a single integrated
decoder. Consequently, the programming sequence
is the same as that of a BiBus door phone.
Press the button on a door unit and digitiser (or the
name button on a call module with repertory), go to
the interface and release the programming button.
The LED will blink to confirm that the programming
operation is complete.
To delete programmed data, hold the programming
button pressed and short-circuit the W1 jumper.
The LED will blink to confirm that the deletion is
complete.
NOTE: The LED will blink also following a door
phone call or floor call.
10 m
50 m
100 m
0.5 mm
2
0.75 mm
2
0,22
mm
2
200 m
6
CV
5