TECHNICAL DATA
TECHNICAL DATA
MOTOR WIRING AND CHANGING VOLTAGE
■ Pumps are Pre-Wired by HP:
1
hp wired for 115 volts
2
3
hp and larger wired for 230 volts
4
WARNING:
DISCONNECT POWER SOURCE BEFORE CHECKING. DO NOT MAKE ANY CHANGES WITH POWER ON.
VOLTAGE CHANGES ARE MADE INSIDE THE MOTOR COVER
NOT IN THE PRESSURE SWITCH
MOTOR DATA
RJ Number
Where Used
SFJ04860EMRD
50SRJ, 50DRJ
SFJ05860EMRD
75SRJ, 75DRJ
SFJ06860EMRD
100SRJ, 100DRJ
Motor Voltage Change
The General Electric and Emerson jet pump motors both have a voltage change switch for ease of changing operating voltage
from low (115 volt) to high (230 volt) operation. The GE switch must be pulled out, rotated and pushed in. The GE motor switch
is marked HI (for 230 v) and LO (for 115 v). The Emerson switch is a toggle that can be changed using a pen tip or a small
screwdriver. The Emerson motor switch is marked 115 and 230.
It is an industry standard procedure to ship
CAUTION
power supply will damage the motor windings, and/or the capacitor, and/or the overload protector. This
damage is easily diagnosed and will not be covered as a warranty failure.
Motors of
3
hp and larger are factory wired for 230 volts. Connecting them to a 115 volt power supply without changing the
4
voltage switch will result in poor performance, noisy operation and overload tripping due to high heat.
8
Emerson Number
HP
Volts
C55JXJRR-4660
1
115/230
2
C55CXJWZ-4732
3
115/230
4
C55CXHKW-4104
1
115/230
1
hp motors wired at 115 volts, connecting them to a 230 volt
2
Phase
Service Factor
Max. Load Amps
1
1.6
12.0/6.0
1
1.5
13.6/6.8
1
1.4
15.8/7.9
Watts
Circuit Breaker
1040
25/15
1380
30/15
1550
30/15