6. Start the inhalation:
Please make sure that the power is turned
on and meets the output capacity of 5V 1A.
Short press the power button of the main
unit to start inhalation.
- Take a slow, deep breath and inhale the medicine.
- For agents with high surface activity or high viscosity, the nebulization
rate may be reduced.
- lt is normal that some sound might be produced by the metal mesh du-
ring nebulization.
- lf the solution has high surface activity, a small amount of the solution
may exudate the metal mesh.
- If the liquid in the medicine cup runs out, press the switch button on
the main unit to turn off the device to avoid potential damage to the
metal mesh.
- When the medication is about to run out, users are advised to tilt the
medicine cup slighlly to themselves to facilitate the remaining liquid to
touch the metal mesh for nebulization.
- When inhaling with a mask, do not cover the mask vent with your hands
or other objects.
- There is a vent on the lid of the medicine cup, please do not cover it with
your hands or other objects, so as not to affect the normal spray.
- During the inhalation, if the user feels uncomfortable, please turn off
the machine immediately and consult the doctor in time.
7. Stop the inhalation:
Short press the power button of the main unit to stop inhalation.
Turn off the external power output and unplug the main unit from the
external power supply.
26
5. Cleaning and disinfection
Clean the medicine cup and mask
1) Remove inhalation mask and medicine cup from the main unit.
2) Open the medicine cup and discard the medication.
3) Add a small amount (2-5ml) of water to the medicine cup, then fas-
ten the lid tightly. Shake the medicine cup gently so that the residual
liquid is fully dissolved in water. Open the medicine cup, pour the
solution out of the cup.
4) Wash the mask in the water.
5) lmmediately after washing the parts, please dry thoroughly in a
clean environment.
6) Store all parts of the nebulizer in a clean place.
Disinfect the medicine cup and mask
1) The medicine cup can be immersed in 75% medical alcohol for more
than 3 minutes, then take out the medicine cup and place it in a clean
place to dry, dry thoroughly and store in a clean place.
2) Use 75% medical alcohol to scrub the mask for more than 3 minutes,
then dry the mask and store it in a clean place.