Installation; General Norms - EQUATION CUBE Manual De Instalación, Utilización Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

TECHNICAL CHARACTERISTICS
STOVE MODEL
Length
Width
High
Weight
Diameter of the suction pipe of the combustion air
Smoke evacuation diameter
Rated thermical power
Reduced thermical power
Heating volume (máx.)
Maximum consum/fuel hour
Minimum consum/fuel hour
Storing capacity
Rated thermical power autonomy
Reduced thermical power autonomy
Rated thermical power efficiency
Reduced thermical power efficiency
Rated power
Max. Electrical power in ignition phase
Rated Electrical voltage
Nominal power frequency
Fuses for the outlet
The table above is based on tests carried out through wood pellets with a calorific value of 18220 kJ/kg (in sum 4.350
Kcal/Kg)
( * ) It is calculated on the basis of water power, according to the installation characteristics at the same time as including
the building insulation. The figures are purely indicative and do not compromise at all the company. The manufacturer
reserves the right at any time to provide new information in order to improve the presentation of the product.

3.0 INSTALLATION

3.1 GENERAL NORMS

It is very important that the installation of the stove is equipped with a proper smoke evacuation system. A faulty
installation of this system is not covered by warranty Ecomasa World Investments. We recommend you to review
the installation, taking into account the following parameters:
Verify the minimum volume of the place where you plan to install. (For instance avoid installing the unit as build in
stove or in spaces of less than 40 m³.)
Ensure proper air flow with an air intake
Respect what is described in the current regulations in force.
Use the smoke evacuation pipes and connections correctly.
The chimney and its pipe should be suitable and fit for the purpose.
The end part of the chimney and the evacuation should be installed according to the current regulations in force as
we commented before.
It should be verified that the following elements are installed according to existing laws:
Prohibition of installation
Legal distance
Limitations sat by regulations or competent authorities.
Conventional limitation following norms, property trade unions and contracts.
It is not possible to install the stove inside bedrooms or bathrooms, or in rooms with a similar heat installation
(chimney, wood stove...) without independent ventilation.
It is totally prohibited to install the product in a location with explosion risk.
CUBE 6 KW
47
cm
41
cm
95
cm
100
Kg
4
cm
cm
8
6.16
KW
KW
2.8
140
Kg/h
1.4
Kg/h
0.6
Kg
17
Heure
12.2
Heure
30
%
87.6
%
91.6
W
120
W
475
V
230
Hz
50
A
2
102
CUBE 10 KW
47
41
95
100
4
8
9.54
2.8
230
2.2
0.6
17
7.7
30
88
91.6
120
475
230
50
2