SPORT-ELEC MULTISPORTPRO PRECISION Manual De Uso página 39

Ocultar thumbs Ver también para MULTISPORTPRO PRECISION:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

GUIDANCE AND MANUFACTURER'S DECLARATION – ELECTROMAGNETIC EMISSIONS
The Multisport Pro Precision is intended for use in the electromagnetic environment specified below. The customer or
the user of the Multisport Pro Precision should assure that it is used in such an environment.
EMISSIONS
COMPLIANCE
RF emissions
CISPR 11
RF emissions
CISPR 11
Harmonic emissions
Not applicable
IEC 61000-3-2
Voltage fluctuations/ flicker
emissions
Not applicable
IEC 61000-3-3
GUIDANCE AND MANUFACTURER'S DECLARATION
The Multisport Pro Precision is intended for use in the electromagnetic environment specified below. The customer or the user of the
Multisport Pro Precision should assure that it is used in such an environment.
IMMUNITY
IEC 60601 TEST LEVEL
TEST
Electrostatic
±6 kV contact
discharge (ESD)
IEC 61000-4-2
±8 kV air
Electrical fast
transient/burst
±2 kV for power supply lines
IEC 61000-4-4
Surge
±1 kV line(s) and neutral
IEC 61000-4-5
<5 % U
(>95 % dip in U
T
for 0,5 cycle
Voltage
dips, short
40 % U
(60 % dip in U
interruptions
T
for 5 cycles
and voltage
variations
70 % U
(30 % dip in U
on power supply
T
for 25 cycles
input lines
IEC 61000-4-11
<5 % U
(>95 % dip in U
T
for 5s
Power frequency
(50/60 Hz)
3 A/m
magnetic field
IEC 61000-4-8
ELECTROMAGNETIC ENVIRONMENT - GUIDANCE
The Multisport Pro Precision uses RF energy only for its internal function. Therefore,
Group 1
its RF emissions are very low and are not likely to cause any interference in nearby
Class B
The Multisport Pro Precision is suitable for use in all establishments, including
domestic establishments and those directly connected to the public low-voltage
power supply network that supplies buildings used for domestic purposes.
ELECTROMAGNETIC IMMUNITY
COMPLIANCE LEVEL
±6 kV contact
±8 kV air
Not applicable
Not applicable
)
T
Not applicable
)
T
Not applicable
)
T
Not applicable
)
T
Not applicable
3A/m
NOTE - U
is the a.c. mains voltage prior to application of the test level
T
electronic equipment.
ELECTROMAGNETIC
ENVIRONMENT - GUIDANCE
Floors should be wood, concrete or ceramic tile.
If floors are covered with synthetic material, the
relative humidity should be at least 30 %.
Mains power quality should be that of a typical
commercial or hospital environment.
Mains power quality should be that of a typical
commercial or hospital environment. If a dips or
an interruption of mains power occurs, the current
of the Multisport Pro Precision may be dropped
off from normal level, it may be necessary to use
uninterruptible power supply or a battery
Power frequency magnetic fields should be at
levels characteristic of a typical location in a typical
commercial or hospital environment.

Hide quick links:

Publicidad

Tabla de contenido
loading

Tabla de contenido