To replace the Equipment Interface Module (EIM)
When you replace an EIM, you must reset the RedLINK accessories before
connecting them to the new thermostat. Follow the instructions below:
At the Portable Comfort Control:
Press and hold the blank space (or arrow) in the lower right
hand corner of the screen until the display changes (hold for
about 4 seconds). Press REMOVE, then YES to disconnect
from the old thermostats. To reconnect the thermostat, go to
Step 4.
At the Indoor Sensor, RedLINK Internet Gateway,
Entry/Exit Remote, Vent-Filter Boost Remote or Wireless
Adapter:
Press and hold the CONNECT button on the accessory until the status light glows
amber (hold for about 10 seconds). To reconnect the thermostat, go to Step 4.
At the thermostat:
Go to Installer Options, Wireless Device Manager, Remove Device, and Select
This Thermostat. Follow the prompts on the screen to connect the thermostat to the
new EIM.
Specifications and replacement parts
Control for up to 4 Heat/2 Cool heat pump systems or up to 3 Heat/2 Cool
conventional systems for residential and commercial applications.
Operating Ambient Temperature
Equipment Interface Module: -40 to 165° F (-40 to 74° C)
Operating Relative Humidity
Equipment Interface Module: 5% to 95% (non-condensing)
Physical Dimensions (height, width, depth)
Equipment Interface Module: 9-5/16 x 4-13/16 x 1-19/32 inches (91 x 147 x 42 mm)
Electrical ratings
Terminal
W - OB
Y (cooling)
G (fan)
W2 - Aux 1 (heating)
Y2 (cooling)
W3 - Aux 2
A-L/A (output)
U1, U1
U2, U2
U3, U3
Voltage (50/60 Hz)
18 to 30 VAC and 750 mVDC
18 to 30 VAC
18 to 30 VAC
18 to 30 VAC
18 to 30 VAC
18 to 30 VAC
18 to 30 VAC
30 VAC max.
30 VAC max.
30 VAC max.
Max. Current Rating
1.00A
1.00A
0.50A
0.60A
0.60A
1.00A
1.00A
0.50A
0.50A
0.50A
13
Portable Comfort