Electrical
Wiring Information
This appliance is equipped with a grounded type power
cord. A grounded outlet must be provided.
The power cord extends 45 outside the unit housing. The
outlet should be located inside the cutout width and below
the lowest most projection of the unit housing.
WARNING
ELECTRICAL
GROUNDING
INSTRUCTIONS
THIS APPLIANCE
IS EQUIPPED
WITH A THREE
PRONG
GROUNDING
PLUG
FOR
YOUR
PROTECTION
AGAINST
SHOCK HAZARD
AND
SHOULD
BE
PLUGGED
DIRECTLY
INTO
A
PROPERLY GROUNDED
RECEPTACLE.
DO NOT
CUT OR REMOVE
THE GROUNDING
PRONG
FROM THIS PLUG.
WARNING
THIS APPLIANCE MUST BE DISCONNECTED
FROM
ITS ELECTRICAL
SUPPLY AT THE WALL RECEP-
TACLE BEFORE SERVICING THE APPLIANCE.
Converting
Appliance
For Use
With LP Gas
WARNING
Propane conversion is to be performed by a JENN-AIR
AUTHORIZED
SERVICER (or other qualified agency) in
accordance with the manufacturer[s
instructions and all
codes
and
requirements
of
the
authority
having
jurisdiction. Failure to follow instructions could result in
serious injury or property damage. The qualified agency
performing
this work assumes
responsibility
for this
conversion.
WARNING
Electrical
power
and
gas must
be turned
off prior to conversion.
Step 3:
Step 4:
Step 5:
Step 6:
Step 7:
Firmly press 9132 (or 7mm) nut driver over
the orifice spud (figure 9) and loosen spud by
turning countercloclwise.
Carefully lift nut
driver out of burner throat. Orifice spud
should be captured in the recess. Repeat this
step for each burner.
Locate the LP orifice spud packet included in
the literature packet. The spuds have small
numbers stamped on the side. This number
codes the orifice diameter and its correct
burner location. Figures on page 7 show the
correct LP orifice spud location.
Carefully install the orifice spud in the
appropriate burner throat by turning clockwise
to tighten. Tighten to a torque of 15 to 20
inch-lbs.
Replace burner base, caps, and grates.
Tighten screws (do not cross thread) to 25-30
inch-lbs.
Save the orifices removed from the appliance
for future use.
REMOVAL OF ORIFICE SPUD
__BURNER
CAP
$CREW$
BuRNt'R
BA_E
This appliance was adjusted at the factory for use with
natural gas. To convert it for use with LP gas (propane or
butane),
each
of the following
modifications
must be
performed:
A=
Replace
all orifice spuds
Step 1 : Remove the grates and burner caps.
Step 2: Remove burner base by removing 2 screws.
(See figure 9.)