TX807 | TX810 | TX815 | TX821
EN
Quick Start Guide
HMI – TX807 | TX810 | TX815 | TX821
Additional documents
The following additional documents are available online at www.turck.com:
■
Data sheet
■
Instructions for use for TX... series
■
Declarations of Conformity (current version)
For your safety
Intended use
The HMIs (Human Machine Interfaces) of the TX800 family are used to control,
operate and monitor machine processes.
The devices are suitable for use in Zone 2 and Zone 22.
The devices may only be used as described in these instructions. Any other use
is not in accordance with the intended use. Turck accepts no liability for any
resulting damage.
General safety instructions
■
The device may only be assembled, installed, operated, parameterized and
maintained by professionally-trained personnel.
■
The device meets the EMC requirements for the industrial areas. When used
in residential areas, take measures to prevent radio frequency interference.
■
The device may only be used in accordance with applicable national and
international regulations, standards and laws.
Notes on explosion protection
■
Observe national and international regulations for explosion protection.
■
When operating the device in a hazardous area, the user must have a working
knowledge of explosion protection (IEC/EN 60079- 14, etc.).
■
Only use the device within the permitted operating and ambient conditions
(see Certification data and conditions resulting from the Ex-approval).
■
This device, with the exception of the front display, is an open device and
must be installed in a housing suitable for the environment, so that the inner
part of the device is only accessible by means of a tool.
■
Do not disconnect devices in an ignitable atmosphere when energized.
■
Do not remove Ethernet connections, USB devices and SD cards in an ignit-
able atmosphere.
■
Do not open the device to remove the battery when energized.
■
Do not remove the battery in an ignitable atmosphere.
■
Switch-off the device before replacing or wiring extension modules.
Note on explosion protection (USA and Canada only)
■
The devices are suitable for the use in Class I, Division 2, groups A, B, C and D
(hazardous locations and non-hazardous locations).
■
The Power, input and output (I/O) wiring has to be done in accordance with
Class I, Division 2 and in accordance with the authority having jurisdictions.
For U.S. in accordance with Article 501.10 (B) of the National Electrical Code,
NFPA 70 and for Canada in accordance with Section 18-1J2 of Canadian
Electrical Code.
■
Use only components that meet Class I, Division 2 certification.
Conditions resulting from Ex approvals for use in Zone 2/Zone 22
Special conditions of use
■
Zone 2 (EPL Gc):
ű
The equipment shall only be used in an area of not more than pollution
degree 2, as defined in IEC/EN 60664-1.
ű
The equipment shall be installed through an end-equipment enclosure
that provides a minimum ingress protection of IP54 in accordance with
EN IEC 60079-0, suitable for the applicable gas group, temperature classifi-
cation and ambient temperature range.
ű
Transient protection shall be provided that is set at a level not exceeding
140 % of the peak rated voltage value at the supply terminals to the equip-
ment.
■
Zone 22 (EPL Dc):
ű
The equipment shall be installed through an end-equipment enclosure
that provides a minimum ingress protection of IP6x in accordance with
EN IEC 60079-0, suitable for the applicable dust group, temperature clas-
sification and ambient temperature.
■
Observe the permissible ambient temperature depending on the tempera-
ture class.
■
Care shall be taken not to allow layers of dust to form on the graphic panel in
a way that might cause the accumulation of static charges.
■
The devices have only been evaluated for low risk of mechanical impact.
Product description
Device overview
See fig. 1.
A
B
C
TX807
187 mm/
147 mm/
176 mm/
7.36"
5.79"
6.90"
TX810
282 mm/
197 mm/
271 mm/
11.10"
7.80"
10.67"
TX815
422 mm/
267 mm/
411 mm/
16.60"
10.50"
16.18"
TX821
552 mm/
347 mm/
541 mm/
21.73"
13.66"
21.30"
Functions and operating modes
The devices of the TX800 series combine control, operation and monitoring by
a CODESYS V3 PLC with integrated visualization to a complete control unit. The
CODESYS V3 PLC of the TX800 devices has the functions PROFINET controller,
EtherCAT master, EtherNet/IP scanner and Modbus TCP as well as Modbus RTU
client. Additionally the devices of the TX800 family can be used as PROFINET
device, Modbus TCP as well as Modbus RTU server.
Additional functions
■
Ethernet TCP/IP or UDP/IP communication
■
OPC-UA server and client
■
Serial communication via RS232, RS485 and RS422
Installing
Mounting the device in Zone 2/Zone 22
DANGER
Explosive atmosphere
Explosion hazard due to ignitable sparks
For use in Zone 2 and Zone 22
Only mount and connect the device if no explosive atmosphere is present.
Observe the conditions resulting from Ex approval for use in Zone 2/Zone 22.
See fig. 2 and 3.
A = TX8...
B = installation cut-out
Mount the device as follows:
Screw each fixing screw until the bezel corner gets in contact with the panel.
The maximum tightening torque is 1.3 Nm.
Select a mounting location so that the device is not exposed to direct sunlight.
Do not cover the ventilation slots in the device.
TX...
Number of brackets included in delivery
TX807
4
TX810
9
TX815
12
TX821
14
Connecting
Connectors and slots
See fig. 4.
Connector/slot
Function
1
USB port, V2.0, max 500 mA
2
Ethernet port 2 (10/100 Mbps)
3
Ethernet port 1 (10/100 Mbps)
4
Serial interface
5
Ethernet port 0 (10/100/1000 Mbps)
6
Power supply
7
2 expansion slots for plug-in modules
8
SD card slot
NOTE
Devices of protection class III according to EN 61140 or Class 2 according to UL
standards:
All connections are SELV connections.
D
E
F
136 mm/
47 mm/
8 mm/
5.35"
1.85"
0.31"
186 mm/
56 mm/
8 mm/
7.32"
2.20"
0.31"
256 mm/
56 mm/
8 mm/
10.00"
2.20"
0.31"
336 mm/
56 mm/
8 mm/
13.22"
2.20"
0.31"
© Hans Turck GmbH & Co. KG | 100048208 2024-03