Descargar Imprimir esta página

Mi-T-M Corporation CD-1002-4MUH Manual Del Operador página 13

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTALLATION & PREPARATION
THERMAL RELIEF VALVE:
To ensure the bypass water temperature does not exceed acceptable levels,
never allow the pressure washer to operate in the bypass mode (with the unit
running and the trigger closed) for more than three minutes.
A thermal relief valve has been added to this unit to protect the pump. It may
begin to open and release water if the water temperature in the pump has
exceeded 190° F. This will allow fresh, cool water to enter the system, therefore
preventing premature failure of pump packings.
PRE-START INSPECTION PROCEDURES:
Before starting the unit, perform the following procedures:
1. Check the oil level in the pump.
2. Inspect the inlet water strainer. Clean or replace if necessary. See
"Water Supply", #2, pg. 11.
3. Check all hose connections to ensure they are securely tightened. See
"Water Supply", #3, pg. 11.
4. Inspect for system water leaks and oil leaks. Be sure that all damaged
parts are replaced and that the mechanical problems are corrected prior
to operation of the unit. If service is needed, contact a Mi-T-M Authorized
Service Center.
5. Inspect high pressure hose for kinking, cuts or leaks. If a cut or leak is
found, DO NOT USE HOSE! Replace hose before starting unit. See
"Miscellaneous Safety Precautions" #6, pg. 6. Be sure that all damaged
parts are replaced and that the mechanical problems are corrected prior
to operation of the unit. If you need service, contact a Mi-T-M Authorized
Service Center.
6. Inspect electrical cord for cuts. If a cut is found, DO NOT TOUCH OR
USE ELECTRICAL CORD! Replace cord before starting the unit.
THE FOLLOWING PAGES CONTAIN OPERATING AND MAINTENANCE
INSTRUCTIONS
DO NOT ATTEMPT TO OPERATE THIS PRESSURE WASHER
UNTIL YOU HAVE READ AND UNDERSTOOD ALL SAFETY PRECAUTIONS
AND INSTRUCTIONS LISTED IN THIS MANUAL.
INCORRECT OPERATION OF THIS UNIT CAN CAUSE SERIOUS INJURY!!
DO NOT ALTER OR MODIFY THIS EQUIPMENT IN ANY MANNER!
Operator's Manual
WARNING
13

Publicidad

loading

Este manual también es adecuado para:

Cd-1502-4muh