ENGLISH
6. Do not place anything on top of the ice
dispenser to obstruct the ventilation louver.
7. T h i s i c e d i s p e n s e r w i l l n o t w o r k a t
subfreezing temperatures. To prevent
damage to the water supply line, drain
the ice dispenser when air temperature is
below zero (see "II. 2. PREPARING THE
ICE DISPENSER FOR LONG STORAGE").
3. INSTALLATION
* Incorrect installation can cause harm to people,
animals or things, for which the manufacturer
cannot be held responsible.
* Secure the ice dispenser to the counter table by
using the brace, machine screws and tapping
screws (accessory). See Fig. 2.
Counter Table
Fig. 2
4. ELECTRICAL CONNECTIONS
WARNING
THIS APPLIANCE MUST BE EARTHED
This ice dispenser requires an earth that
meets the national and local electrical code
requirements. To prevent possible severe
electrical shock to individuals or extensive
d a ma g e t o e q u i p m e n t, i n sta l l a p r o p e r
earth wire to the ice dispenser. Remove
t h e p l u g f r o m t h e m a i n s s o c k e t b e f o r e
any maintenance, repairs or cleaning is
undertaken.
* Th i s a p p l i a n c e r e q u i r e s a s e p a r a te 2 2 0 -
240VAC, 13A supply. The electrical supply must
be protected by a suitable circuit breaker.
* The main control box fuse is rated at 5A and
should only be replaced by a qualified service
engineer.
* Usually an electrical permit and services of a
licensed electrician are required.
* If the supply cord and the plug should need to be
replaced, it should only be done by a qualified
service engineer.
For the U.K. and the Republic of Ireland only
* The wires in the mains lead are coloured in
accordance with the following code:
As the colours of the wire in the mains lead
of this appliance may not correspond with the
coloured markings identifying the terminals in
your plug, proceed as follows:
The wire which is coloured Green-and-Yellow
must be connected to the terminal in the plug
Machine Screw
which is marked with the letter E or by the symbol
Tapping Screw
or coloured Green or Green-and-Yellow. The
wire which is coloured Blue must be connected
Brace
to the terminal which is marked with the letter N
or coloured Black. The wire which is coloured
Brown must be connected to the terminal which
is marked with the letter L or coloured Red.
* Should the socket outlets in the installation site
not be suitable for the plug supplied with your
product, the plug must be removed (cut off if it is
moulded on plug) and an appropriate plug fitted.
If the non-rewirable plug has been cut from the
power supply cord, it must be disposed of. There
should be no attempt to reuse it. Inserting such a
plug into a socket elsewhere presents a serious
risk of electrical shock.
* The non-rewirable plug must never be used
without a fuse cover being fitted.
The correct replacement for the detachable fuse
cover is identifiable from the manufacturer's
reference number stamped on the plug.
Supply of replacement fuse covers can be
obtained from Hoshizaki Parts/Service Centres.
Fuses should be rated at 13A and approved to
BS 1362.
2
Green & Yellow = Earth
Blue = Neutral
Brown = Live