EN
Technical data
Table 1:
Controller input
Max. input voltage (Voc)
55 V DC
Operating voltage
24...55 V DC
Max. current (DC)
6 A
Max. pv short circuit
25 A
current (Isc)
Controller output
55 V BLDC PWM
Max. output voltage
3-Phase
Max. frequency
170 Hz
Max. continuous current
6 A
Max. continuous power
250 W
Case
Enclosure class
IP 68
Protective class
II
General
System storage
-20 °C... +65 °C
temperature
[-4 °F...+149 °F]
Pollution degree
3
classification
Max. altitude rating
2000 m [6560 ft]
Overvoltage category
OC II
input/output
Controller ambient
-30 °C... +50 °C
temperature
[-22 °F...+122 °F ]
Max. water temperature
50 °C [122 °F]
(pump and motor)
Refer to Table 2
l
Explanation of warning symbols
a
WARNING
– Disregard can lead to
injury, death or damage the system
O
CAUTION
– Recommended to avoid
dysfunction or premature ageing of the
equipment etc.
INFORMATION
- Refer to the
respective document.
WEEE
- The WEEE Symbol means
that a device must be disposed of
separately from general household
waste. When a device reaches the end
of its lifespan, it must be taken to a
designated waste collection point for
safe disposal or recycling.
l
When installing and using this electrical
equipment, basic safety precautions should
always be followed, including the following:
WARNING
– To reduce the risk of
injury, do not permit children to use
this product unless they are closely
supervised at all times
WARNING
– To reduce the risk of
electric shock, replace damaged cords
immediately
WARNING
- Due to local laws an
external fuse might be necessary
WARNING
– When the photovoltaic
array is exposed to light, it supplies a
DC voltage to the controller
WARNING
- Make sure that the
controller is unplugged when
installing the pump system
l
WARNING
- Do not try to open
the controller. This will damage the
controller and voids the waranty
WARNING
- Only connect
equipment that was provided by the
manufacturer or supplier to this pump
WARNING
– Disconnect power from
the controller before disconnecting
the motor.
a
WARNING
– Disconnect power then
disconnect the pump cable before
attempting to clean the pump
CAUTION
– This pump is only for use
in water only. It is not certified for salt
water or swimming pool use.
CAUTION
– Do not connect the pump
to any other controller other than
the one supplied with the pump. Do
not use the controller with any other
pump.
CAUTION
- Keep pump out of direct
sun during installation to avoid
overheating.
CAUTION
- We recommend to use
O
only one extension cable. Using
multiple extension cables will reduce
system performance.
INFORMATION
– This pump and
controller are certified for indoor and
outdoor use
Temperature classes
Ensure the pump class is suitable for the water
temperature. See Figure 1 and Table 2.
Table 2: Meaning of temperature classes:
Temperature
Water temperature range
class
2
20 to 30 °C [68 to 86 °F]
3
30 to 40 °C [86 to 104 °F]
4
40 to 50 °C [104 to 122 °F]
Figure 1: Pump end naming
PE S1-HR-XX-2-PASN-FNXX-HA
PE
Pump end type
S1
07
14
HR
23
XX
X
Temperature class:
2
= 20 to 30 °C [68 to 86 °F]
PASN
3
= 30 to 40 °C [86 to 104 °F]
FNXX
4
= 40 to 50 °C [104 to 122 °F]
HA
Maintenance / servicing
There are no user serviceable parts in the
controller or motor. Do not open the controller
or motor
Check cables for signs of wear or damage
before each use. If cables are worn or damaged
please refer to the retailer or supplier of the
pump system.