Descargar Imprimir esta página

SICK WLF4F Instrucciones De Uso página 25

Fotocélulas miniatura
Ocultar thumbs Ver también para WLF4F:

Publicidad

10
Technical specifications
Sensing range (with reflector PL80A)
Sensing range max. (with reflector PL80A)
Light spot size / distance
Supply voltage U
B
Ripple
Output current I
max.
Current consumption
Switching frequency
Response time
Enclosure rating
Protection class
Circuit protection
Ambient temperature, operation
1)
Limit values
Reverse polarity protected U
B
Residual ripple max. 5 V
ss
2)
Without load. For U
= 24 V.
B
3)
With light / dark ratio 1:1
4)
Signal transit time with resistive load
5)
A = U
-connections reverse polarity protected
B
B = inputs and output reverse-polarity protected
C = Interference suppression
D = outputs overcurrent and short-circuit protected
8027380.1N1Y/2024-03-11 | SICK
Subject to change without notice
Cleaning
NOTICE
Equipment damage due to improper cleaning.
Improper cleaning may result in equipment damage.
Only use recommended cleaning agents and tools.
Never use sharp objects for cleaning.
Clean the optical surfaces at regular intervals and, in the event of contamination,
with a lint-free lens cloth (part number 4003353). The cleaning interval essentially
depends on the ambient conditions.
No modifications may be made to devices.
Subject to change without notice. Specified product properties and technical data are
not written guarantees.
connections
OPERATING INSTRUCTIONS
WLF4F
0.4 m ... 7 m
0.4 m ... 10 m (Typ)
Ø 40 mm (1.0 m) (Typ)
DC 10 ... 30 V
1)
≤ 5 VSS
≤ 100 mA
25 mA
2)
1000 Hz
3)
≤ 500 μs
4)
IP66, IP67
III
A, B, C, D
5)
–40 °C ... +60 °C
O P E R A T I N G I N S T R U C T I O N S | WLF4F
en
25