9.3
Engage the wires (d) on the wire guides (e) according to their colours.
9.4
Cut off the projecting wire ends flush, i.e. without protrusions.
9.5
Push the union nut (c) onto the electrical T-distributor (f) and tighten it to the required
torque (1.2 Nm).
Caution!
Note the polarity.
The same wire colour must be in the same wire guide for both union nuts.
When tightening the union nut, the electrical contact and tension relief are created
automatically.
Special seals act as protection from dust and water.

10. Assembly

Preparing the electrical connection
The power supply should be installed in a separate room outside the wet area and
secured with a residual current device (RCD).
10.1 Install the cistern (a).
10.2 Install the electrical T-distributors (b, c) (see
10.3 Attach the motor (d) inside the cistern (see MBA 01805697).
10.4 Connect the motor (d) to the first electrical T-distributor (b).
10.5 Engage the pressure coil of the cistern (a) on the motor (d).
10.6 Use the adhesive tape to attach the electronic module (K) to the motor.
10.7 Connect the wires between the electronic module, the motor and the piezo button.
A: Actuator cable (motor)
B: Actuator cable (optional)
C:0-10 V analogue output
D:Cold water temperature sensor (optional)
E: Hot-water temperature sensor (optional)
F: Connection for the sensor to be provided by the customer (e.g. door contact or
trigger device for disabled persons)
G:Piezo button
H:Electrical T-distributor system cable (power)
K: Electronic module
10.8 Connect the cable of the motor (d) to the cable (A) of the electronic module (K).
10.9 Fit the protective cap onto the sensor connection (F) of the electronic module.
or
Connect the sensor to be provided by the customer (e.g. door contact).
Chapter
9.).
- 6 -