Descargar Imprimir esta página

Key Automation 14AF Instrucciones Y Advertencias Para Su Instalación Y Uso página 27

Central modular para uno o dos motores de 24 vcc

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 50
4.6 - Diagnostic
A number of parameters, including the current absorption or motor speed, can be viewed at any time using this function. Proceed as
follows:
14A
4.7 - Customising the system - Basic settings
If necessary, users may select the BASIC SETTINGS, which allow
modification of the control unit's basic parameters.
Proceed as follows:
14A
BASIC SETTINGS
PARAMETERS
Automatic reclosure time (0 = off)
AUTOMATIC
1
Seconds of delay before the gate recloses
CLOSING TIME
automatically after opening
Reclosing time after transit (0 = off) Seconds
AUTOMATIC
of delay before the gate recloses automatically
2
CLOSING AFTER
after excitation of photocell 1 during opening or
TRANSIT
with the gate open.
Motor sensitivity, sensitivity when detecting an
obstacle.
0 = minimum sensitivity, maximum force on
3
SENSITIVITY
obstacle
10 = maximum sensitivity, minimum force on
obstacle
Motor speed during opening
1 = minimum
OPENING
2 = low
4
SPEED
3 = medium
4 = high
5 = maximum
Motor speed during opening deceleration phase.
1 = minimum
SLOW DOWN
2 = low
5
OPENING SPEED
3 = medium
4 = high
5 = maximum
Motor speed during opening deceleration phase.
SLOW DOWN
1 = minimum
5
OPENING SPEED
2 = low
FASTLINE
3 = medium
Motor speed during closing
1 = minimum
2 = low
6
CLOSING SPEED
3 = medium
4 = high
5 = maximum
DIAGNOSTIC
DESCRIPTION
MOTOR 1 CURRENT (mA)
MOTOR 2 CURRENT (mA)
MOTOR 1 POSITION (%)
MOTOR 2 POSITION (%)
MOTOR 1 SPEED (%)
MOTOR 2 SPEED (%)
TOTAL CYCLES (CYCLES)
CYCLES LEFT BEFORE SERVICE
SOFTWARE VERSION
CAUTION: the parameters may vary with respect to those in
the table below, depending on the motor to be installed.
DEFAULT
MIN.
0
0
3
4
1 *
1
4
MAX.
UNIT
0
900
s
0
30
s
0
10
1
5
1
5
1
3
1
5
EN
27