5 Installation
5.1 – Hydraulic Installation
The hydraulic inlet must reach the bath
with mixed water (hot and cold) from the floor.
Mixers must be previously installed on the wall.
Check the suggested location for water
and sewage installation for the bathtub model
requested on item 7 – Dimensions.
INLET
Models Viena, Paris and Versalhes do
not have a water inlet installed in the bathtub
hull. They must be supplied by an external spout,
or a floor stand faucet, which can be purchased
separately.
For models Londres and Liverpool, install
the water inlet as shown on Fig. 1.
For models Amsterdam, Tokyo, Van-
couver and Verona, hydraulic inlet must be con-
nected to a 1/2" flexible hose found in the inner
edge (Fig. 2).
OVERFLOW
Viena model does not have an overflow.
For models Londres and Liverpool, do
the overflow installation as shown on Fig. 3. First
drill the space for the overflow on drain with a 20
mm drill. On the other models the overflow is
already installed.
SEWER
For all the models: For sewage con-
nection, use a flexible trap connected to the
outlet elbow of the bathtub (Fig. 4).
Connect the other end of the flexible trap
to the pipeline previously installed on the floor
(Fig. 5).
The sewage pipeline must be 40mm and
must be connected to a catch basin to avoid the
return of unpleasant smell back to the bathtub.
10
1
Hot water
1/2" water inlet
connection (thread)
3/4" drain connection
(smooth)
2
flexible hose
3
2
1
4
5
1/2" water inlet
connection (thread)
3/4" drain connection
(smooth)
Mixer
Cold water
Water inlet
3
4
5
1 - Plastic outlet valve 40mm"
2 - Plastic water inlet
3 - Elbow 25mm - 90º*
4 - Brown pipe 25 x 40*
5 - Spiralled hose*
*Not included