To activate setting mode, proceed as follows:
Remove battery (K) and insert again
after 5 seconds, see Abb. [10].
Setting mode is automatically terminated
after 3 minutes.
Setting the flow volume
The factory-set flow volume is approx. 3 litres at
a flow pressure of 3 bar.
The flow volume can be changed as follows:
1. Activate setting mode.
2. Hold hand at a distance of approx. 5 – 10cm
in front of the sensor system in the fitting.
The indicator lamp in the sensor system of the
fitting flashes rapidly:
3. The indicator lamp extinguishes automatically
after approx. 5 seconds.
4. Remove hand from the detection zone
(at least 60cm).
5. Again hold hand at a distance of
approx. 5 – 10cm in front of the sensor system.
The flow volumes are indicated via the indicator
lamp in the sensor system by groups of flashing
signals separated by a pause.
6. Flow volumes and display:
The number of flashing signals of the
consecutive groups corresponds to the following
flow volumes:
2 = flow volume 2 litres
Pause
3 = flow volume 3 litres (factory setting)
Pause
...
7 = flow volume 7 litres
Pause
After the group with 7 flashing signals,
the routine starts from the beginning.
7. Selecting the flow volume
The flow volume is selected by removing the
hand from the detection zone (at least 60cm)
in the pause after a group of flashing signals.
Once the hand is removed, the fitting
immediately flushes with the selected flow
volume (the corresponding flashing signals
are displayed again during flushing).
5
8. The flow volume can be readjusted within the
next 20 s if necessary by again holding the hand
at a distance of 5 – 10cm in front of the sensor
system (see point 5).
The selected flow volume is accepted as the
new setting and setting mode is automatically
terminated if there is no hand in front of the sensor
system 20 seconds after flushing. The area directly
in front of the sensor system must be kept free from
objects for these 20 seconds as otherwise the flow
volume will be unintentionally adjusted once more.
- Fit cap (F) again and fasten with screw (E),
see Fig. [8].
Additional functions of the urinal fitting
The following settings can be made and changed
with the remote control (Prod. no.: 36 206):
Switch on/off 24-hour flush
(factory setting: switched on)
1. Press and hold the RESET button.
2. Then additionally press the OFF AUTO button
within 2 s.
The indicator lamp in the sensor system of the
fitting flashes:
- 4 x short = 24-hour flush is switched on,
No-use flush interval: 24 hours.
- 2 x long = 24-hour flush is switched off.
Switch on/off intermediate flush
(factory setting: switched on)
1. Press the TEST button => test mode is switched
on.
2. Press the OFF AUTO button as required.
The indicator lamp in the sensor system of the
fitting flashes:
- 4 x short = intermediate flush is switched on,
- 2 x long = intermediate flush is switched off.
Setting mode is quit by pressing the TEST button,
or automatically after 60 sec.