Descargar Imprimir esta página

Grohe 43 863 Manual De Montaje página 7

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 13
GB
Application
Urinal radar system as replacement for
• DE 540 and replacement parts
• 205.00.007 supplied up to 1995
• 205.00.020 (42 509) supplied up to 1986
• 205.00.023 (42 510) supplied up to 1986
• 205.00.030 (42 511) supplied up to 1986
• 205.00.200 (42 513) supplied up to 1999
• 205.00.201 (42 514) supplied up to 1999
• 205.00.210 (37 000) supplied up to 2004
Safety notes
• In the case of damage to the external transformer and
control unit connection cable, this must be replaced by the
manufacturer or his customer service department or an
equally qualified person, in order to prevent a hazard.
• Use only genuine replacement parts and accessories.
The use of other parts will result in voiding of the warranty
and the CE identification.
Technical Data
• Supply voltage:
(transformer 230 V AC/12 V AC)
• Power consumption:
• Operating frequency:
• Reception range:
(adjustable from step 1 – 9)
• Flow volume:
(adjustable 1 – 7 l)
• Intermediate flush:
• Automatic flush:
• Type of protection:
Electrical test data
• Software class:
• Contamination class:
• Rated surge voltage:
• Temperature of ball impact test:
The test for electromagnetic compatibility (interference
emission test) was performed at the rated voltage and rated
current.
Special accessory
• Infrared remote control (Prod. no. 36 206) for changing the
factory settings and selecting special functions.
Approval and conformity
This product conforms to the requirements of the
relevant EU guidelines.
The conformity declarations can be obtained from the
following address:
GROHE Deutschland Vertriebs GmbH
Zur Porta 9
D-32457 Porta Westfalica
Operation
The subsurface-installed sensor monitors the detection range
and detects movements. If the user remains within the
detection range for longer than 7 s (= minimum delay time),
the solenoid valve opens and the bowl is flushed:
- Approx. 1 s after the user moves away
- After approx. 5 s, if the sensor does not detect any
movement
- After 2 min, if constant movement is detected.
Operating display flashing signal
The indicator lamp (A1) in the display (A2) of the electronics
module (A) displays the three operating states, see Fig. [1]:
- Standby: a flashing signal approx. every 2 seconds
- Movement detected in front of the urinal (user approaching):
a flashing signal every seconds
230 V AC, 50/60 Hz
- User detected and minimum dwell time elapsed:
two flashing signals every second.
3.2 VA
24.075 GHz to 24.175 GHz
Step 5
Preparations
3 l (factory setting)
1. Remove the inspection cover.
Every 2 min (max. 14x)
If the sensor is installed behind the urinal, remove the urinal.
(factory setting: activated)
2. Close isolating valve (H), see Fig. [2].
24 hours
(factory setting: activated)
3. Detach plug-in connector.
IP 54
4. Remove controller (I) and solenoid valve (J), see Fig. [3].
5. Remove radar sensor (K), see Fig. [4].
Installing sensor
A
The sensor box can be replaced if necessary.
2
Polystyrene sensor box, see fold-out page II, Fig. [5]:
2500 V
1. Remove sensor (B) from plate.
100 °C
2. Fit sensor (B) in sensor box.
3. Fasten sensor (B) with retaining tabs (C).
4. Route sensor cable (B1) through tube (D) to wall mounting
box.
Plastic sensor box, see fold-out page II, Fig. [6]:
1. Fit sensor (B) with plate in sensor box.
2. Route sensor cable (B1) through tube (D) to wall mounting
box.
Installing solenoid valve
Install solenoid valve (E) with seals (E1), see Fig. [7].
Important: Install solenoid valve in flow direction.
Installing urinal
Open isolating valve (H), see Fig. [8].
0682
!
; 0700 !
Switch off voltage supply!
4

Publicidad

loading