Battery Installation And Battery Type Setting (Wet Or Gel/Agm) - Nilfisk-Advance EcoFlex SC3000 Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

6/14

BATTERY INSTALLATION AND BATTERY TYPE SETTING (WET OR GEL/AGM)

Battery installation
1.
Open the cover (20) and check that the recovery tank (19) is empty, otherwise empty it with the drain hose (24).
2.
Close the cover (20).
3.
Carefully lift the tank assembly (44).
4.
Install the batteries and connect them according to the diagram (38).
Battery type setting
Set the machine electronic board and the battery charger according to the type of batteries installed (WET or GEL/AGM) as shown
below:
5.
Turn the ignition key (58) to "I" and, in the very first seconds of machine operation, detect the current setting by counting the
number of flashes of the battery warning lights (62), as shown in the following table:
SETTING
DISPLAY (71)
1
2
6.
If the setting is to be changed, perform the following procedure.
7.
Turn off the machine by turning the ignition key (58) to "0".
8.
Press and hold the switches (67) and (63) at the same time, then turn the ignition key (58) to "I".
9.
Release the switches (67) and (63) at least 5 seconds after starting the machine.
10. Within 3 seconds, shortly press the switch (63) to go to the next setting (1 to 6 in cyclic sequence).
NOTE
When performing steps 9 and 10, the settings are shown on the display (71) too, by the code in the table.
NOTE
The battery charger must be set according to its own User manual.
Battery charging
11. Charge the batteries (see the procedure in Maintenance chapter).
10/10
INSTRUCTIONS FOR USE
BATTERY WARNING LIGHT INDICATION (62)
4 flashes of the red warning light
4 flashes of the green warning light
9098827000 - SC3000 26 D
BATTERY TYPE
WET
GEL-AGM