ENGLISH
VACUUM SYSTEM MOTOR FILTER CLEANING
1.
Drive the machine on a level floor.
2.
Turn the ignition key (58) to "0".
3.
Open the cover (20) and check that the recovery tank (19) is empty, otherwise empty it with the drain hose (24).
4.
Close the cover (20).
5.
Carefully lift the tank assembly (44).
6.
Check that the filter (37) is clean. If necessary clean it with water and compressed air, then install it.
SOLUTION FILTER CLEANING
1.
Drive the machine on a level floor.
2.
Turn the ignition key (58) to "0".
3.
Close the solution valve (A, Fig. 7) under the machine, behind the right rear wheel. The valve (A) is closed when it is in the
position (B) and it is open when it is in the position (C).
4.
Remove the transparent cup (D), recover the gasket (E), then remove the filter strainer (F) under the machine, in front of the
right rear wheel. Clean them with water and install them on the support (G).
NOTE
The filter strainer (F) must be correctly positioned on the housing of the support (G).
5.
Open the valve (A).
C
A
24
INSTRUCTIONS FOR USE
B
SC3000 26 D - 9098827000
G
F
E
D
Figure 7
H
1/14
P100370
10/10