swallowing or suff ocating!
•
Upholstery nozzle
•
Crevice nozzle
•
Combination nozzle
•
Extension tube
•
Filter
•
Wall holder
•
Original operating instructions
•
Safety information
3. Proper use
The vacuum cleaner is designed for dry vacu-
uming using the appropriate fi lter. The equipment
is not suitable for the vacuuming of combustible,
explosive or harmful substances.
The equipment is to be used only for its prescri-
bed purpose. Any other use is deemed to be a
case of misuse. The user / operator and not the
manufacturer will be liable for any damage or inju-
ries of any kind caused as a result of this.
Please note that our equipment has not been de-
signed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
machine is used in commercial, trade or industrial
businesses or for equivalent purposes.
4. Technical data
Motor power supply: ............................... 18 V DC
Tank volume: ...............................................0.54 l
Weight: .....................................................0.85 kg
Caution!
The equipment is supplied without batteries and
without a charger and is allowed to be used only
with the lithium-ion batteries of the Power-X-
Change series!
The lithium-ion batteries of the Power-X-Change
series are allowed to be charged only with the
Power-X charger.
Suitable batteries and chargers from the Power
X-Change series are for example.
•
Battery: Power X-Change 1.5
•
Battery: Power X-Change 3.0
•
Charger: Power X-Charger 3A
•
Charger: Power X-Charger
Anl_TC_HSS_18_Li_SPK7.indb 15
Anl_TC_HSS_18_Li_SPK7.indb 15
GB
5. Before starting the equipment
Warning!
Always remove the battery pack before making
adjustments to the equipment.
5.1 Assembling the equipment
Fitting the nozzles (Fig. 1-2)
The nozzles (5, 6, 7) can be fi tted to the vacuum
cleaner either directly on the intake opening (10)
or via the extension tube (8).
Fitting/removing the fi lter (Fig. 1-4)
Press the locking switch (4) and remove the tank
at the same time (3). You can then take the fi lter
(9) out of the tank (3) (Fig. 3).
The fi lter (9) must be completely taken apart to
enable it to be thoroughly cleaned (Fig. 4).
After cleaning, fi t the fi lter (9) back in the tank (3)
(Fig. 3). Then fi t the tank (3) back on the vacuum
cleaner (Fig. 5).
Fitting the wall holder (Fig. 8)
Fit the wall holder (11) as shown in Fig. 8.
Suitable fastening materials such as screws etc.
(Ø 4 mm) are available from your dealer.
The holder provides a practical means of storing
the handheld vacuum cleaner after use (Fig. 9).
Important!
The wall holder is only suitable for use with Ein-
hell cordless handheld vacuum cleaners. It is not
suitable for bigger loads!
5.2 Suction nozzles
Combination nozzle (Fig. 2)
The combination nozzle (7) is for vacuuming so-
lids over medium to large areas.
Crevice nozzle (Fig. 2)
The crevice nozzle (6) is designed for vacuuming
solids in corners, edges and other areas that are
diffi cult to access.
Upholstery nozzle (Fig. 2)
The upholstery nozzle (5) is specially designed
for vacuuming solids on upholstery and carpets.
5.3 Charging the battery (Fig. 6-7)
1. Take the battery pack out of the equipment.
Do this by pressing the side pushlock buttons.
2. Check that your mains voltage is the same as
that marked on the rating plate of the battery
- 15 -
20.07.2023 08:51:05
20.07.2023 08:51:05