Descargar Imprimir esta página

Gaggenau AR 413 722 Instrucciones De Instalación página 11

Módulo del ventilador

Publicidad

Idiomas disponibles

Idiomas disponibles

Additional switching output
9
WARNING
Work must only be carried out on the additional
switching output by a qualified electrician in
accordance with the country-specific
requirements and standards.
The appliance has an additional switching output X16
(potential-free contact) that can be used to connect
other appliances, such as a ventilation system that is
available at the installation site. The contact is closed
when the fan is switched on, and is opened when the
fan is switched off.
The switching output is located under a cover. Maximum
switching power 30 V/1 A (AC/DC). The signal that is
connected to the contact must correspond to class of
protection 3.
Networked operation
Several appliances can be networked together. The
light and fan on each of the appliances are operated
synchronously.
Connect the appliances in series via the connector
sockets X1 and X2 (equal value). The sequence of the
networking does not have any effect. If the enclosed
network cables are too short, use a commercially
available network cable (min. Cat. 5, shielded).
Maximum number of networked appliances: 20. Total
length of all of the network cables: 40 m. During the
initial installation, a qualified electrician must check
that the system functions correctly.
If one of the networked appliances fails (power
interruption, network cable disconnected), this leads to
the fan function being blocked for the entire system. All
of the buttons on the appliance flash.
When changing the configuration, the system must be
re-initialized:
1
Unscrew the cover plate.
2
Press and hold the reset button until both LEDs
light up continuously (approx. 5 seconds). Then
release the button within 5 seconds.
3
Screw on the cover plate.
4
After initialization, have a qualified electrician
check that the system functions correctly.
Connect Electrical Supply
9
WARNING
Before you connect an electrical cord for
permanent connection or turn on power supply,
make sure all controls are in the OFF position.
9
WARNING
Risk of electric shock
Parts inside the appliance can have sharp edges.
The connection cable can be damaged. Do not
bend or pinch connection cables during
installation.
Attach flexible conduit to the junction box. The junction
box must be accessible after installation.
To facilitate serviceability, the flex conduit should be
routed to allow for temporary removal of the appliance.
Check the Installation
Switch on the circuit breaker.
Verify that elements function properly.
Removing the appliance
Disconnect the appliance from the power supply.
Remove the control cable. Undo the exhaust
connections. Pull out the appliance.
11

Publicidad

loading