Installation
Connect appliance
The appliance has to be connected to the power supply
by means of a 3-wire conduit installation with a 1 inch
conduit.
1
Remove terminal block cover by unscrewing the
3 fixing screws and lift it off.
2
Guide conduit through the opening for electrical
connection in the holding fixture
3
Secure the conduit with the ring nut
4
Connect the wires of the power cord with the
terminal block
and tighten terminal screws
(C)
securely. Connect as follows:
‒ L = connect to hot wire
‒ N = connect to neutral wire
<
= Connect to ground wire
5
Connecting the network cable
Use the control cable to connect the remote fan unit and
the fan. The plug must snap into place.
Note: The X1 and X2 connection sockets are identical.
Installing the appliance
1
.
(A)
(B)
.
Replace terminal block cover and fasten it with the
3 fixing screws.
Shorten the connecting hose to the required length.
Mount the ends on the filter unit and base fan.