EN
taneously again for 3 seconds.
After unlocking, "UL" will appear briefly.
5
USE WITH GATEWAY WFC03
Note: the WFC03 gateway is not included in the package but
is an accessory to be purchased separately.
This gateway only works with the RC22OTRF (knowable by
the icon in the label placed inside the case back).
By associating the WFC03 gateway with RC22OTRF, and in-
stalling WFC03 in the home WLAN network, it is possible to
manage the room temperature and the operation of the con-
trolled unit remotely via APP.
APP is available on the APPLE Store or Play Store.
To know how associate and remove the zone/remote to the
gateway and for WLAN installation, refer to the APP itself
where there is a guided procedure.
6
GENERAL INFORMATIONS
The remote control can provide the user with information on
boiler status.
Each press of the button
following information:
T1 - Heating circuit delivery water temperature
T2 - Domestic hot water temperature
T3 - Heating circuit return water temperature (boilers with
sensor only)
- 24 -
allows the cyclic display of the
T4 - Delivery water temperature setpoint calculated by the
remote control
P5 - Actual burner power
F6 - Actual fan speed (condensing boilers only)
F7 - Actual DHW flowrate (instant hot water boilers with flow-
meter only)
P8 - Actual system pressure (boilers with pressure sensor
only)
P9 - Rate request for cooling calculated by the Remote (if the
controlled unit is enabled to function)
M - Device model
V - Device software version.
7
FAULTS
E91 = communication error with the boiler
E92 = room temperature reading probe not working
E93 = external temperature reading probe not working
AXX = anomaly XX of the boiler not unlockable
FXX = anomaly XX of the unlockable boiler.
8
RESTORING FACTORY SETTING
Important: with this procedure the device parameters will be
restored to the factory set values, except for the time and day
setting.
To reset user setting will be necessary to push the buttons
and
together for 10 seconds (the message RE flashing
is displayed).