4.1 Measurement
2. Press the ''backfat scan'' button to measure.
Put the probe on the measuring point and squeeze the air and air bubbles between the probe and
the skin.
If there is no backfat reading in 15 seconds, the device will beep three times "Dididi" and exit the
backfat scan. You can restart the measurement by pressing the "backfat scan" button.
Warning: It is necessary to confirm that the probe is perpendicular to the measuring point
to avoid erroneous measurement result.
- If there is no backfat reading in 15 seconds, the device will beep three times "Dididi" and exit the
backfat scan. You can restart the measurement by pressing the "backfat scan" button.
- If a stable backfat reading is displayed, the device will beep for "Di...", exit the backfat scan, and
display the thickness and number of layers on the main interface, as shown in Figure 4-2.
MANUAL DE INSTRUCCIONES / INSTRUCTION MANUAL
Figure 4-1 Backfat measure interface
Figure 4-2 Backfat display interface