Install the unit at a dry place
Connecting
AquaMax Eco Expert 20000 / 12 V
• Hoses or pipes can be connected at the inlet and outlet. Recommendation:
– Up to 5 m length: Use 50 mm (2") hose sleeves and hoses.
– From 5 m length: Use DN 75 or DN 100 pipes.
• The pump can handle particles with a size of up to 11 mm. Larger particles will clog the pump.
We recommend installing a filter or skimmer on the intake side.
AquaMax Eco Expert 27000 / 12 V
• A DN75/100 pipe is connected to the inlet. A hose or a pipe can be connected to the outlet.
Recommendation:
– Up to 5 m length: Use 50 mm (2") hose sleeves and hoses.
– From 5 m length: Use DN 75 or DN 100 pipes.
• The pump can handle particles with a size of up to 11 mm. Larger particles will clog the pump.
We recommend installing a filter or skimmer on the intake side.
Connect pipes with a PVC transition sleeve with a female thread (→ Technical data). PVC
transition sleeves are available in specialised shops.
Do not plug the power plug into the socket yet!