Code
Name
P0
Mandatory defrosting
P1
Working mode
P2
Timer on/off
P3
Water pump
P4
Current time
P5
Timer on
P6
Timer off
P7
Water temp. calibration
Restore to factory
P14
settings
P16
Product code
P18
Mode
Note:
1). Long press
for 20s to set P14, P16, P18.
2). P8,P9,P10,P11,P19,P20 parameter is only for factory setting.
5.2.7 System reset function
Press
, then press
for 20s, in which parameter will flash. Press
settings.
5.2.8
Symbol of TIMER ON, the light will be on when the value of P2 is 1, which means TIME ON & OFF function is working.
Then set the current time(Parameter P4), TIMER ON (Parameter P5) and TIMER OFF (Parameter P6). All the symbols
(except symbol
) on the display will be off when TIMER is OFF.
Note: The symbol
Scope
0-1
0-1
0-1
0-1
HH:MM
HH:MM
HH:MM
-9~9
0-1
/
0-1
to choose P14, and enter into the value setting interface by long press
keeps on when restart the heat pump after TIME OFF, unless the value of P2 is set to 0.
Default
0: Default normal operation
0
1: mandatory defrosting.
1
1:Heating mode, 0:cooling mode,
1 Timer on/off is under function, 0 Timer on/off is out
0
of function (The setting of P5 and P6 won't work)
1:Always running;
0
0:Depends on the running of compressor
00:00
0-23:0-59
0-23:0-59
00:00
0-23:0-59
00:00
0
Default setting: 0
1-Restore to factory settings,
0
0- default(restore P0, P1, P2, P3, P5, P6, P7, P8, P9,
10, P11 to factory setting)
/
Depends on the machine
1—Heating only,
0
0—Heating/Cooling/Auto mode
to set the value 1, finally press
or
61
Remark
to save