<<2-zone temperature control>>
● A thermistor is built in the remote controller (Room RC) or the main controller (Main RC), or
TH1. The indoor unit refers to temperature monitored by a selected thermistor and controls
temperature for each zone.
● For 2-zone temperature control, one room sensor can be selected for Zone1 and Zone2 sep-
arately. The room sensor is used for monitoring room temperature.
● The selection of room sensor can be fixed or changed according to time, using a schedule
timer.
Note: Room sensor can be selected by main controller only.
Indoor unit
Receiver
* When
is shown on the remote controller, this indicates that the remote controller is used for
monitoring the room temperature. In this example, the living room temperature monitored by
remote controller 1 is regarded as the room temperature for Zone1. The bed room 2 temperature
monitored by remote controller 4 is regarded as the room temperature for Zone2.
9. Specifications
Power source
Operating temperature and humidity re-
quirements
Weight
Dimension (W×H×D)
Supplementary information
10.
Product fiche of temperature control
(a) Supplier's name: MITSUBISHI ELECTRIC CORPORATION
(b) Supplier's model identifier: PAR-WT50R-E and PAR-WR51R-E
(c) The class of the temperature control:
(d) The contribution of the temperature control to seasonal space heating energy efficiency: 4%
19
Zone1
Living room Dining room
Address 1
Item
Bed room 1 Bed room 2
Address 2
Description
12V DC (powered by indoor unit)
Temperature: 0 to 40°C
Humidity 30 to 90%RH (No condensation)
150 g (excluding a cable)
100 mm × 80 mm × 30 mm
Zone2
Address 3
Address 4