ENGLISH
heating mode, the condensate drainage will be done through the lower condensate outlet.
Note: when changing from heating mode and vice versa, the appliance will take some time
to change from one mode to the other. It may take a few minutes for the appliance to start
running normally again.
Sleep mode
In cooling mode, press the increase and decrease icons to activate the Sleep mode. The device
will operate saving energy and silently.
Increase and decrease icons
Use these icons to increase or decrease temperature and time.
Temperature cannot be increased or decreased in fan or dehumidification mode.
Fan speed
Under the cooling mode, press the key to select high or low wind speed operation.
This option is not available under the dehumidification mode.
NOTE:
Under certain conditions (defrost), it may not operate at the selected speed.
Timer
-
Press this key to set the timer. When the timer symbol blinks, use the increase and decrease
icons to select the desired operating time.
-
The timer can be set from 1 to 24 hours, and the digits increase and decrease by 1 hour.
Unit switch: (Remote control)
Press this button to switch between ºC and ºF.
Oscillation
Press this button to activate the air oscillation.
Drainage instructions
When the air conditioner stops operating because the water tank is full, turn it off and unplug
it from the power supply. The full-tank indicator (FL) will start blinking on the display and the
appliance will not operate until the water inside the tank is drained.
Manual drainage. Fig. 10
1.
Place a container below the water outlet behind the body.
2.
Unscrew the drain cap and unplug the water plug. The water will automatically flow into
a container.
64
FORCECLIMA 14600 SOUNDLESS HEATING
NOTE:
-
Move the device carefully, so as not to spill the water in the water tank at the bottom of
the body.
-
Keep the drain cap and the water plug properly.
-
During drainage, the body can be tilted slightly backwards.
-
If the water container cannot hold all the water, before the water container is full, stuff the
water outlet with the water plug as soon as possible to prevent water from flowing to the
floor or the carpet.
-
When the water is discharged, re-tighten the water plug and tighten the drain cap.
-
Restart the appliance after the plug and cap are installed, otherwise condensed water of
the appliance will flow to the floor or the carpet.
Continuous drainage. Fig. 11
1.
Unscrew the drain cap and unplug the water plug.
2.
Set the drainage pipe into the water outlet.
3.
Connect the drainage hose to a bucket or big container.
Protection features:
Frost protection function
In cooling and dehumidification modes, if the temperature of the evaporator outlet pipe is
too low, the appliance will automatically enter protection mode to prevent damage to the
evaporator. The appliance will restart when the temperature is restored to normal values.
Condensate water flooding protection function
When the water level exceeds the maximum level allowed by the safety buoy, the appliance
will switch off and activate the FL indicator on the control panel. To restart the device, the
water inside the device will need to be drained through the bottom drain plug (shown in detail
in the drainage instructions section). Once the water has been drained, the device will restart.
Automatic defrost
This air conditioner has an automatic defrost function.
Compressor protection function
To increase the service life of the compressor, it has a 3-minute delay booting protection
function after the compressor is turned off.
ENGLISH
FORCECLIMA 14600 SOUNDLESS HEATING
65