Temperature setting of
refrigerating chamber
Press temperature zone selection
button
setting temperature zone of
refrigerating chamber, and then
press
or
to adjust the setting
temperature of refrigerating
chamber. The temperature setting
range for refrigerating chamber is
2°C ~ 8°C.
•
Temperature setting of freezing
chamber
Press temperature zone selection
button
the setting temperature zone
of freezing chamber, and then
press
or
to adjust the setting
temperature of freezing chamber.
The temperature setting range for
refrigerating chamber is -24°C~
-16°C.
•
Temperature setting of variable
temperature chamber
Press Variable temperature button
to adjust the setting
temperature of the chamber, the
adjusting range is Fruit/vegetable,
drink and meat.
Fruit/vegetable:Suitable for
storing all kinds of fruits and
vegetables;
Drink:Suitable for storing dry
goods and drinks;
Meat::Suitable for a small
amount of meat stored for 1-2
days
•
Mode setting
Set the Super cooling mode:
after the temperature of the
refrigeration room is adjusted
to 2°C, press the temperature
down button "
super cooling mode. In the super
cooling mode, the temperature
to choose the
to choose
" to enter the
EN-15
of the refrigerating chamber is
automatically set to 2°C.
Exit the Super cooling mode:
press the temperature up button
"
" to exit the super cooling
mode or automatically exit the
super cooling mode after 6h.
After exiting the super cooling
mode, the temperature of the
refrigerator will automatically
return to the temperature set
before the super cooling mode
Set the super freezing mode:
after the temperature of the
freezing chamber is adjusted to
-24°C, press the temperature
down button "
super freezing mode. In the super
freezing mode, the temperature
of the freezing chamber is
automatically set to -24°C
Exit the super freezing mode:
press the temperature up button
" " to exit the super freezing
mode or automatically exit the
super freezing mode after 43h.
After exiting the super freezing
mode, the freezing chamber
temperature will automatically
return to the temperature set
before the super freezing mode
According to IEC62552:2007,the
Refrigerating capacity test condition as
follow:start the super freezer mode in
advance,and wait when the fridge enters
automatic defrosting after 18 hours,and
then apply the freezer load.
The maximum defrosting time is 96 hours
and the minimum is 12 hours at 32°C.
When conducting power consumption
tests, set the vario temp to Fruit/
vegetable.
Recommended setting :
Refrigerated chamber 4°C freezing
chamber -18°C.
" to enter the