INSTALLING PUMP KIT
DISCONNECT ELECTRICAL POWER
WARNING
Death or serious injury can result from failure to
follow these instructions.
• Service by a qualified service technician only.
• Disconnect power before servicing this product.
• Reconnect all grounding devices after service.
• Replace all parts and panels before operating.
1
REMOVE ACCESS COVER
Use a drill or a Phillips screwdriver to remove the
2 screws from the access panel as shown in figure
below. Slide the panel in the direction shown to
remove.
2
Installation Instructions
Electrical Shock Hazard
Screws
Access
Panel
Slide panel in
this direction
(Cont.)
2
REMOVE DRAIN TUBING
Remove the plastic snap ring from the main drain
tube and release the small metal clamp on the
short drain tube which connected outlet valve. Pull
both tube down. Remove the small metal clamp
from the tube. Keep both snap ring and clamp for
pump kit installation
Remove the white drain pipe by pulling it down
from the 2 locations shown.
3
INSTALL RUBBER PAD TO NEW
PUMP
Remove the rectangular rubber pad from pump
kit and peel off the white sticker. Attach the sticky
side to the drain pump base.
White Sticker
Rubber Pad -
Sticky side up
Snap
Outlet
Ring
Valve
Main
Drain
Tube
Small
Metal
Clamp
Short
Drain
Tube
31-1000617 Rev. 3