INSTALLING PUMP KIT
6
CONNECT DRAIN PUMP TO ICE
MACHINE (Cont.)
Locate the male 4-pin
white pressure sensor
connector behind
the bracket hole,
loosen the wire tie
and connect the pig
tail to the pressure
sensor located on the
drain tube assembly.
If the male 4-pin
white pressure sensor
connector is not showing
in the access opening
area, locate the connector
in the nearby machine
compartment area and connect it to pressure
sensor on the drain tube assembly. The 4- pin
male connector within the ice machine will match
up with the 4-pin female connector on the pressure
sensor. Note: the yellow connector within the ice
machine should not be used.
Lower the pump and make
sure the drain tube is not in
a horizontal position.
Attach the pressure sensor assembly in the 3 holes
of the flange of the ice machine, as shown, using
the screw provided with the kit.
Thread the drain hose into the round hole in the
back of the ice machine case and attach to the
nozzle on the top of the drain pump using the large
metal clamp.
Back of Ice Maker
Drain Hose
4
Installation Instructions
(Cont.)
Pressure Switch
Assy from Drain
Pump
Pressure Sensor
Connector from
Ice Machine
White pressure sensor
connector is tied behind
the flange.
Pressure Switch Assembly
Screw
Drain Hose
Large Metal Clamp
Nozzle
6
CONNECT DRAIN PUMP TO ICE
MACHINE (Cont.)
IMPORTANT
the machine cabinet using the green ground wire,
locking washer and screw. The grounding hole is
marked with a grounding symbol.
7
CHECK PUMP OPERATION
(DO NOT SKIP THIS STEP)
Restore power to the unit.
Pour several quarts of water into
the bin, the drain pump should
turn on and pump the water out
of the bin automatically, cycling
on and off several times during
the process is normal. Check
the connections if pump had no
response.
While the pump is discharging
water, THOROUGHLY CHECK
THE ENTIRE DRAIN SYSTEM
FOR LEAKS.
8
FINALIZE INSTALLATION
Re-install side panel using the screws removed
in step 1.
Re-install unit into built-in or free-standing
location. ENSURE THAT NO KINKS OCCUR
IN WATER INLET OR DRAIN TUBING. Double-
check for leaks!
Restore potable water supply and restart the
unit. Check unit to ensure proper operation and
to allow a final check for leaks of any kind.
Ground the pump to