Descargar Imprimir esta página

Klafs 18029 Instrucciones De Servicio página 33

Publicidad

Idiomas disponibles

Idiomas disponibles

Sauna/SANARIUM
8.
If something does not work
8.2.
Other possible errors
Fault
The controller
cannot be
switched on.
The cabin light
does not light up
after having been
switched on.
The fan is not
working.
No power at
output AG1.
No power at
output AG2.
Fan cannot be
adjusted.
50701290/12.14
Cause
No mains power available.
Fuse SI102 or SI104 has
blown.
The bulb is defective.
No mains power.
Light fuse SI103 has blown.
No mains power.
Fuse SI104 has blown.
The fan is defective.
The main switch is not
switched on.
Fuse AG2 SI101 has blown. Replace fuse AG2 SI101 (1.25 AT) or
The controller is in standby
mode.
Climate Manager is
connected.
Remedy
Check the FI switch and the fuse in the
power supply.
Replace fuse SI102 (1.6 AT) or
SI104 (1.0 AT), or inform Klafs service
engineers.
Change the bulb.
1.
Disconnect the controller from the
mains.
2.
Replace with a bulb of the same
wattage.
Check the FI switch and the fuse in the mains
supply.
Replace light fuse SI103 (0.6 AT) or inform
Klafs service engineers.
Check the FI switch and the fuse in the
power supply.
Replace fuse SI104 (1.0 AT) or inform Klafs
service engineers.
Replace the fan.
1.
Disconnect the controller from the
mains.
2.
Replace with a fan of the same
wattage.
Switch on the main switch.
inform Klafs service engineers.
Start a bathing mode.
.
The air flow rate is regulated by the
Climate Manager.
'
See operating instructions.
Continued on the next page
Continued
PAGE 33

Publicidad

loading

Productos relacionados para Klafs 18029

Este manual también es adecuado para:

1803318040