Safety
instructions
• You MUST wear rubber gloves and hold with your
thumb and forefinger, then insert the electrode pipe
till its tightly fitted.
.You MUST wear rubber gloves. It is strictly prohibited
to push the electrode pipe with your palm.
• When in use, the high voltage current output from
the electrotherapy tube will cause interference.
• lt is farbidden to approach the host machine and
other electrical appliances of the high-frequency
electrotherapy beauty instrument. lf it interferes with
the host, it may cause the host to not work or crack.
• When the electrode tube is less than 2.5cm from
the skin but not in contact with the skin, the current
intensity should be reduced immediately if sparks
emits to irritate the skin. lf the customer still feels the
spark after the above operation, a small piece of dry
cotton towel (nylon or other synthetic fiber towels are
not allowed) put on the customer's face.
• When using, always keep the electrode tube on the
customer's skin. High-frequency indirect care: when
turning on and off the instrument, one hand must
always be in contact with the customer's skin, never
leave the customer's skin. Both sides feel the current
and it causes discomfort.
• Turn off the power befare pull out the power cord
plug after use, and pull out the electrotherapy tube
from the high-frequency electrotherapy handle,
then sterilize and keep it dry befare putting it into
the accessory box.
© 2024 Weelko / www.weelko.com / Importer: Weelko Barcelona, S.L. /
HF Electrodes
1.
• Ref. 10009
• Ladle-shaped electrode pipe: used for medium
areas of skin (chin, etc). fig.1
2.
• Ref. 10010
. Straight electrode pipe: used for indirect treatment.
3.
• Ref. 10011
. Mushroom-shaped electrode pipe: used for large
areas of skin (face, forehead, neck, etc).
4.
• Ref. 10012
. Ball-like electrode pipe: used for small areas of skin
(nose, etc).
5.
• Ref. 10040
. High frequency handle. Electrode holder.