Descargar Imprimir esta página

Dometic VMD2.5 Display Instrucciones De Montaje Y De Uso página 5

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

12.1
Home screen
This section shows the location of the controls and status indicators on the Home screen
and describes their use.
6
5
2021.06.18
09:00 AM
4
3
2
Auto
1
14
13
1
Fan speed indicator
2
Mode indicator
3
Scheduler indicator
4
Quiet mode indicator
5
Alarm indicator/control
6
Eco mode indicator
7
Temperature up control
Table 1: Home screen controls and status indicators
Icon
Control/indi-
cator
Mode indicator
Mode: Cool
C ool
Mode: Heat
H e at
Mode: Auto
Mode: Fan only
Inside
70 F
8
RH 60%
Cool
12
11
8
Temperature/set point indicator
9
Temperature down control
10
Relative humidity indicator
11
Power control
12
Main menu control
13
Mode control
14
Fan speed control
Description
The mode icon shows the current operating mode.
The icon is animated when the compressor is running
and static when it is not running. The icon flashes
when the compressor cycles off and enters a three-
minute delay mode before it can cycle back on.
The system will run a cooling cycle when the cabin
temperature rises above the cooling set point by the
set point differential. The default set point differential
is 2 °F (1.1 °C). Refer to
Parameters
on page 7 to
learn how to adjust the set point differential. Icon will
animate when the compressor is operational.
The system will run a heating cycle when the cabin
temperature falls below the heating set point by the
set point differential. The system will cycle off when
the temperature set point is exceeded by 1 °F (0.6
°C). Refer to
Parameters
on page 7 to learn how
to adjust the set point differential. Icon will animate
when the compressor is operational .
The system will automatically switch between a cool-
ing and a reverse (heating) cycle depending on
whether the cabin temperature goes above or below
the set point by 4 °F (2.1 °C).
The system will run the fan to circulate the air continu-
ously turning on the compressor.
Icon
A uto
7
9
10
70 F
RH 60%
Control/indi-
Description
cator
Fan speed indi-
The indicator shows the selected fan speed. In
cator
modes other than Fan Only, the indicator shows Au-
to, indicating that the fan speed is following the com-
pressor speed. This is the ideal setting for true vari-
able capacity performance. The icon is animated
when the fan is running and static it is not running.
Refer to
Parameters
on page 7 to learn how to
adjust the low and high fan speeds. Icon will animate
when the fan is operating.
Scheduler indi-
The indicator appears when a scheduled program is
cator
active. Refer to
Scheduler mode
learn how to turn Schedular mode on/off and set up
and run programs.
Alarm indica-
This indicator appears when there is an active alarm.
tor/control
Clearing the alarm notification does not resolve the
alarm. The alarm notification will reappear on the
Home screen until the problem is resolved. Refer to
Troubleshooting
for information on resolving alarms.
• Tap the Alarm indicator to display the current
alarm.
• If there are more than two alarms, tap the Up
Arrow and Down Arrow to navigate through
the Alarm list.
• Tap an alarm from the list to view the details.
• Tap CLR to clear an individual alarm from the
Alarm Details screen.
Quiet mode in-
The indicator appears when the function is active.
dicator
Refer to
Quiet mode
on page 6 to learn how to
turn Quiet mode on/off and adjust the set point.
Eco mode indi-
The indicator appears when the function is active. Re-
cator
fer to
Eco mode
on page 6 to learn how to turn
the mode on/off and adjust the set point.
Up arrow
Tap to raise the temperature on the Home screen.
On other screens, tap to navigate to the earlier menu
and/or raise a numerical value.
Tempera-
The indicator displays the new temperature set point
ture/set point
while the temperature set point is adjusted with the
indicator
Up Arrow or Down Arow, then displays the tempera-
ture in the cabin.
Down arrow
Tap to lower the temperature on the Home screen.
On other screens, tap to navigate to the next menu
and/or lower a numerical value.
Relative humidi-
The indicator displays the relative humidity in the
ty indicator
cabin if a humidity sensor is installed.
Power control
The power button turns the system on or off. When
on, the system will run in the selected mode when
the cabin temperature is higher (Cool mode) or low-
er (Heat mode) than the set point. When off, the sys-
tem will not run although it will stay in communica-
tion with the network (if present).
Tap and hold to toggle the power on or off.
    EN
on page 6 to
5

Publicidad

loading

Este manual también es adecuado para:

9600025911