EN Dometic Hipro Care
NOTICE! Damage hazard
• Do not use abrasive cleaning agents or hard objects during cleaning as these can damage the de-
vice.
• Never use hard or sharp tools to remove ice or to free frozen objects on the device.
• Do not use any mechanical tools or any other tools to speed up the defrosting process.
• The light source can only be replaced by the manufacturer, a service agent or similarly qualified per-
son to avoid hazard.
Clean the device regularly and as soon as it becomes dirty with a damp cloth.
Wipe the device dry with a cloth after cleaning.
Check the condensate drain regularly.
Clean the condensate drain when necessary. If it is blocked, the condensate collects on the bottom of the de-
vice.
For absorber versions: Use a brush or so cloth annually to remove dust from the absorber unit.
10 Troubleshooting
Problem
The mini fridge is not cooling. The in-
dicator LED is off.
The mini fridge is not cooling. The in-
dicator LED is on.
Mini fridge is not cooling. Indicator
LED flashes orange for x times within a
certain period of time.
14
Possible cause
Power plug is not plugged in.
No voltage at the socket.
The fuse of the electronics is defective.
For versions with absorber cool-
ing: Heating cartridge defective
Electronics or temperature sensors de-
fective.
Cooling unit is defective.
Mini fridge is in silent mode (C60 on-
ly).
Flashing 1x: NTC sensor is defective.
Suggested remedy
Insert power plug into socket.
Check circuit breaker.
Contact an authorized service
agent.
Service agent only: Replace
the fuse.
Contact an authorized service
agent.
Service agent only: Install new
heating cartridge.
Contact an authorized service
agent.
Service agent only: Install new
electronics or sensor.
Contact an authorized service
agent.
Service agent only: Replace
the mini fridge.
No action required
(Setting the silent
mode (only for C60SBI, C60SFS)
page 13).
Contact an authorized service
agent.
Service agent only: Replace
the NTC sensor.
on